Troubleshooting
Smart Power Supply Error Code 7 Flow Chart 1P "Speed
Compare Error (7)"
1P
Is the Red LED D13
flashing 7 times with 4
second pause on the
Smart Power Supply
PCBLF0443-1?
Yes
Turn the treadmill power
switch OFF (O).
Verify the harness between Drive PC2303-012-N
and Smart Power Supply PCBLF0443-1 is properly
connected and not damaged.
Verify the harness between Motor
00101-03 and Drive PC2303-012-N is properly
connected and not damaged.
Turn the treadmill power switch
OFF (O) for 10 seconds then turn
the power switch ON (-).
Is the Red LED D13 on
No
the Smart Power
Supply PCBLF0443-1
on continuously?
Go To
Page 1I
A
94
No
PMC5FA-
Yes
T2100-ST1 Treadmill, 110V / T2100-ST2 Treadmill, 220V
Yes
Go To
Page 1I
Is the Red LED D13
flashing on the Smart
Power Supply
PCBLF0443-1?
Was the harness
Yes
damaged?
No
Was the harness
No
properly
connected?
Yes
Was the harness
Yes
damaged?
No
Was the harness
No
properly
connected?
Yes
No
Treadmill should
be operational.
Replace Harness
10 Pin Harness
Connect harness.
Replace Motor
Connect harness.
B
2097937-002 Rev G