8.
9.
10.
11.
12.
13.
14.
15.
2097937-002 Rev G
11 March 2019
VonWeise Actuator
b.
If the cam was turned to adjust the lower switch; the upper
cam will need to be reset to zero to allow the treadmill to
park in the correct position. Repeat step 4 to 5 to
reestablish 0% elevation.
NOTE:
When an adjustment on VonWeise Actuator is made
to the lower cam, the upper cam moves in tandem.
On MSI Actuator when an adjustment is made to the
lower cam, the upper cam does not move in tandem.
When the desired results are achieved change the
481
value back to
.
Test 0.5%
Select
.
Using the tape measure, verify the elevation height is within
specification +/- 2%,
Refer to the "Elevation Chart" on page 174.
If incorrect, compensate by making small incremental
adjustments of 1 to 5 counts in
the elevation grade being tested by typing the new value and
OK
selecting
or pressing
Test 0.5%
Select
and recheck the measurement.
NOTE:
When selecting the grade being tested, the treadmill will
change elevation.
Repeat steps 9 through 12 for 5%, 10%, 15%, 20%, and 25%.
Cycle the power to return the treadmill to 0% elevation.
If the actuator cap was removed, replace the cap.
T2100-ST1 Treadmill, 110V / T2100-ST2 Treadmill, 220V
MSI Actuator
Elevation Count
Enter
.
Calibration
Test 25%
column next to
173

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

T2100-st2

Table of Contents