8.

Replacing the Relay

Tools Required
o
o
o
1.
2.
3.
4.
5.
6.
2097937-002 Rev G
11 March 2019
Reverse step 1 through step 7 to reinstall replacement CE
Filter.
#8-32 Nut
CE Filter
Flat Head Screwdriver
Grounding Wrist Strap
Pliers or adjustable wrench
Approximate time to complete: 20 min
Turn treadmill main power switch to the OFF position.
Unplug the treadmill plug from the wall receptacle.
Allow the treadmill to discharge for 1 minute.
Remove the (5) hood-securing bolts.
Remove the hood and set it aside.
CAUTION:
Use ESD precautions, including wearing a grounding
wrist strap that is connected to an exposed metal
connection point on the treadmill chassis. Put on the
grounding wrist strap and ground it to the power cord
ground screw.
With pliers remove the quick disconnect wires connection
from the relay.
Note the wire's location for replacement.
T2100-ST1 Treadmill, 110V / T2100-ST2 Treadmill, 220V
Component/FRU Removal and Replacement
#8-32 Screw