Pull Tether Flow Chart 1F
1F
Is the Red D12
LED lit on Smart
Power Supply
PCBLF0443-1?
No
Verify treadmill power switch is
in the off (0) position.
Verify the Pull Tether Clip
connected to Pull Tether.
Turn treadmill power switch in
the on (1) position.
2097937-002 Rev G
11 March 2019
LED lit on Smart
Yes
Go To
Verify wire connectors on the Emergency
Chart 1G
Stop and quick disconnect on connector
J6 & J7 are a secure connection on Smart
Power Supply PCBLF0443-1.
Replace Pull
Tether.
T2100-ST1 Treadmill, 110V / T2100-ST2 Treadmill, 220V
No
Is the Red D12
Power Supply
PCBLF0443-1?
Verify the continuity of the Emergency
Yes
Stop Harness with an OHM meter to
Go To
ensure the wire is not damaged.
Chart 1G
Is the Red D12
LED lit on Smart
Power Supply
PCBLF0443-1?
Yes
No
Troubleshooting
Verify treadmill power switch is
in the off (0) position.
No
Wires
Damaged?
Replace
Emergency
Stop Harness.
Turn treadmill power switch in
the on (1) position.
Red D12 LED Light should be lit
on Smart Power Supply
PCBLF0443-1 Reference 1E.
83
Yes