Smart Power Supply Error Code Identification Flow Chart 1I - GE T2100-ST1 Service Manual

Hide thumbs Also See for T2100-ST1:
Table of Contents

Advertisement

Troubleshooting

Smart Power Supply Error Code Identification Flow Chart 1I

Verify the error code by counting the flashes.
The error flashes are very consistent and
then a long pause.
Reference Smart Power Supply Error Code, 1
Flow Chart 1J. Reason for error flashes Bad
Calibration Error (1).
Reference Smart Power Supply Error Code 2,
Flow Chart 1K. Reason for error flashes
Elevation Error (2).
Reference Smart Power Supply Error Code 3,
Flow Chart 1L. Reason for error flashes Zero
Speed Motor Controller Error (3).
Reference Smart Power Supply Error Code 4,
Flow Chart 1M. Reason for error flashes Over
Speed Motor Controller Error (4).
Reference Smart Power Supply Error Code 5,
Flow Chart 1N. Reason for error flashes Zero
Speed External Sensor Error (5).
Reference Smart Power Supply Error Code 6,
Flow Chart 1O. Reason for error flashes Over
Speed External Sensor Error (6).
Reference Smart Power Supply Error Code 7,
Flow Chart 1P. Reason for error flashes Speed
Compare Error (7).
86
T2100-ST1 Treadmill, 110V / T2100-ST2 Treadmill, 220V
Is the Red LED D13
Yes
flashing on the
Smart Power Supply
PCBLF0443-1?
No
Verify the Emergency Stop Button is
released or Pull Tether missing.
Verify when the Emergency Stop
Button is released the Smart Power
Supply PCBLF0443-1 initial power up
returns to the parked position.
Treadmill should
be operational
Reference Smart Power Supply Error Code 8,
Flow Chart 1Q. Reason for error flashes
Motor Control Fault Signal (8).
Reference Smart Power Supply Error Code 9,
Flow Chart 1R. Reason for error flashes Belt Start
Reject Error (9).
Reference Smart Power Supply Error Code 10,
consult the factory for trouble shooting.
1I
.
2097937-002 Rev G
11 March 2019

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

T2100-st2

Table of Contents