Component/FRU Removal and Replacement

Replacing the Stop Tether Switch (STS)

Tools Required
o
o
o
o
1.
2.
3.
4.
5.
6.
7.
150
1/8" Allen Wrench
¼" Flat Blade Screwdriver
Long Nose Pliers
Grounding Wrist Strap
Approximate time to complete: 30 min
Turn the treadmill main power switch to the OFF position.
Unplug the treadmill plug from the wall receptacle.
Allow treadmill to discharge for 1 minute.
With a 1/8" Allen wrench, remove the (2) 10-32 screws (Fig. A)
holding the STS assembly to the fabricated handrail.
Fig. A
10-32 Screw
ESB or STS
Assembly
Fig. B
With a flat head screwdriver, remove the STS assembly
from the fabricated handrail (Fig. B).
CAUTION:
Use ESD precautions, including wearing a grounding
wrist strap that is connected to an exposed metal
connection point on the treadmill chassis.
Completely remove the STS assembly and gently pull to
expose the wires.
With a pair of long nose pliers, remove the two STS
connector wires from the outside terminals of the tether
assembly (Fig. C).
NOTE:
When reconnection wires be sure to locate the
connector on the outer terminals.
T2100-ST1 Treadmill, 110V / T2100-ST2 Treadmill, 220V
1/8" Allen
Wrench
Screwdriver
Fabricated
Handrail
2097937-002 Rev G
11 March 2019