Component/FRU Removal and Replacement
26.

Replacing the Motor Drive Belt

Tools required
o
o
o
o
o
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
140
See "Running Belt Tension Adjustment" on page 42.
Reinstall the hood.
1/4" Hex Wrench or Hex Socket
3/4" Open-end Wrench & Hex Socket
1/4" Hex Nut Driver or Flat Blade Screw Driver
Grounding Wrist Strap
Tape Measure
Approximate time to complete: 1 hr 20 min
Elevate the treadmill to 12%.
Turn the treadmill main power switch to the OFF position.
Unplug the treadmill plug from the wall receptacle.
Allow the treadmill to discharge for 1 minute.
Remove the (5) hood-securing bolts.
Remove the hood and set it aside.
CAUTION:
Use ESD precautions, including wearing a grounding
wrist strap that is connected to an exposed metal
connection point on the treadmill chassis.
With the ¾" wrench and socket, loosen spring tension and
the slide belt off the sprocket, allowing the motor to pivot.
With the 7/16" socket and wrench, remove the (6) bolts
securing the Bracket Motor Right Hand.
Loosen the rear belt tension bolt, allowing the rear roller to
move forward towards the front roller.
Remove the hex socket head cap screw, retaining the front
roller on the right hand side.
Lift right hand end of the front roller enough to remove the
drive belt.
Reverse the procedure to install the new drive belt.
After installation of the new drive belt, perform "Running
Belt Tracking Adjustment" on page 59 and "Running Belt
Tension Adjustment" on page 60.
T2100-ST1 Treadmill, 110V / T2100-ST2 Treadmill, 220V
2097937-002 Rev G
11 March 2019