10.2 List of status messages

Message Status Name
a) Alarms, faults
1
StSy
1
StSy 2
1
St.4
1
St.5
1
St.6
1
St.7
1
St.8
1
St.9
2
St.4
2
St.5
2
St.6
Application Manual
Description, Procedure
Restart
If this message appears whilst in operation, the device is faulty.
 Contact the Honeywell Technical Assistance Center.
Data error
An error was detected during the cyclic check of the data subject
to calibration regulations.
 Contact the Honeywell Technical Assistance Center.
Vm-Alarm
No volume was recorded at the used input for conversion.
(Automatic switching to a second pulse generator as described in
 chapter
C-fact. err.
The conversion factor could not be calculated as the measured
gas temperature was outside 100°C to +100°C or no usable
compressibility ratio factor was available.
T Alarm Lim.
The gas temperature measured is outside acceptable limits.
The limit values can be changed when putting the device into
operation in the presence of a calibration officer ( Operating
Instructions [1]).
p Alarm Lim.
The measured gas temperature is outside the permissible limits.
The limit values can be changed when putting the device into
operation in the presence of a calibration officer ( Operating
Instructions [1]).
K-val. error
The compressibility ratio factor could not be calculated as no valid
real gas factor could be determined.
z-fact. err.
The real gas factor could not be calculated.
At least one of the gas analysis values Ho.n, CO2, H2, rhon, is
outside the permissible range.
Vm Inp. error
No volume at measurement conditions was recorded at the
connected encoder on input 1 for 40 seconds (with external power
supply) or for one measurement cycle + 1 second (battery
powered).
T Inp. error
The gas temperature cannot be measured due to a fault.
 Contact the Honeywell Technical Assistance Center.
p Inp. error
The gas pressure cannot be measured due to a fault.
 Contact the Honeywell Technical Assistance Center.
4.4
(p. 27) is not configured).