EK280
7.1.6.3.2 Preparation
Initial conditions:
The SIM card is inserted as described in  chapter
The SIM card is unlocked as described in  chapter
For the following parameterization the EK280 power supply must first be switched off.
7.1.6.3.3 Opening the customer lock
In order for ComFTP to read data from the EK280 and save it on the server, at least one EK280 lock must be
permanently open. For this purpose it is recommended to use the customer lock, as this contains the least
write permissions and therefore avoids the risk of unauthorized parameter updates.
Move the cursor to the "Serv." tab in the EK280's display, then to
(customer lock status).
If "open" is displayed below
If "locked" is displayed under
key on the keypad, enter the single digit customer lock with the keypad.
The default customer lock setting is "0". After pressing
"open" is now displayed under St.CL.
In order to ensure the customer lock is not automatically closed again, Move the cursor further down
to
AutCL
and make sure that
If
"0
minutes" is not displayed under AutCL, set the value after pressing the
keypad to "0" and save the input with the
7.1.6.3.4 Parameterization of the EK280 for operation with a ComFTP modem
i
For parameterization of the EK280 you need a connection cable for the optical interface as well
as the enSuite program. enSuite can be downloaded free of charge from the Honeywell website
in the "Software Downloads" section:
www.elster-instromet.com/en/software-downloads
In order to parameterize the ComFTP modem, you also need a USB parameterization cable
(Honeywell Order No.: 730 20 481) for connection to the modem parameterization interface
(located on the EK280 CPU board) or a functioning GSM/CSD connection. The settings in the
ComFTP modem can be made with enSuite V3.4 or higher.
Information regarding the USB modem configuration cable
If this cable is plugged into the modem configuration cable ( Fig. 9, p. 74), then the connection
between the EK280 and modem is interrupted (parameterization mode). The EK is unable to
exchange any data with the modem when in this state.
a) Closing the time windows
In order that the parameterization works correctly the time windows 1 to 4 must be closed. To do this:
Connect a PC or laptop with enSuite installed to the EK280 optical interface using the connection
cable.
Start enSuite and set up the communication link to the EK280 using the optical interface.
( chapter
3.1 Setting up the communication link to the EK280 via optical
To do this select "Navigation" on the left-hand side and then
the navigation window.
Application Manual
7.1.2
St.CL
the customer lock is already open.
St.CL
move the cursor over to
"0
minutes" is displayed here.
ENTER
key.
(p. 58).
7.1.3
(p. 61).
Device settings > Access > St.CL
Cod.C
and after pressing the
ENTER
to commit the change, check that
ENTER
interface, p. 19)
"Parameterize