Logged on to own network; level is 77% and therefore in the acceptable range: Since the system
status shows no entries, the device is also externally supplied (no battery operation)
The level is also relatively constant (no fluctuations or break in of the level)
Modem logged out, although mains power supply is on!
 Call window closed?
 No connection to the GSM network possible (GSM station switched off...)!
Modem logged out, battery powered! The modem was unable to log on, as the external power
supply failed!
 E.g. Maybe the EK280 is connected to the lighting system by mistake, so the power to the EK280
is switched off when the light is switched off.