4.1.2 Parameterization
Parameterization is carried out via the keyboard on the EK280.
Alternatively, parametrization can be carried out using the enSuite program. The paths which are
subsequently described can be found in enSuite under
Setting the input mode
−
Open the administration lock as described in the EK280 Operating Instructions.
−
Move the cursor to the "Serv." tab and via the path below go to the input mode "Md.I1":
Serv.
Inputs
−
Press the ENTER key. ⇒ The set value flashes.
−
Repeatedly press one of the or arrow keys until the text
−
Press the ENTER key to confirm the value setting. Input can be canceled using the ESC key.
Setting the cp (pulse constant) value
−
Move the cursor to cp value "cp.I1" in the same path.
−
Press the ENTER key. ⇒ One of the value's digits flashes.
−
Move the cursor to the digits using the or arrow keys and update them using the or arrow
keys.
−
Press the ENTER key to confirm the value setting. Input can be canceled using the ESC key.
−
Close the administration lock of the EK280.
Setting the counter value
−
If necessary, the meter reading of the gas meter can be set as the starting value for the volume at
measurement conditions Vm. The procedure is described in chapter 2.4.4.
Application Manual
Input 1
Md.I1.
"Parameterize
online" > "Parameters".
"pulse
input" flashes.
23