Honeywell EK280 Applications Manual page 109

Volume converter
Hide thumbs Also See for EK280:
Table of Contents

Advertisement

EK280
Switch on the EM260 power supply.
Now, under "Parameters" > "Interfaces" >
6. After opening the time window, the Ethernet adapter is automatically parameterized by the EK280
(as of V2.40)
The Ethernet adapter is configured after approx. 30s. You can check whether the parameterization
has been carried out on the connection status of the corresponding connection profile (time window
5 = connection 5) (setpoint = 4: Die Schnittstelle ist bereit..." (The interface is ready).
7.3.3.3 Checking accessibility
Make sure that the Ethernet connecting cable of the EM260 is connected with your network (LAN).
In order to be able to verify the Ethernet card configuration, have your network administrator execute
a ping command to the corresponding IP address (e.g., ping 192.168.0.5.). This will ensure that the
IP address is registered within the network and valid.
7.3.3.4 Retrieving data with enSuite
a) Opening the test time window for the following test retrievals with enSuite.
i
The test time window only needs to be open if none of the time windows 5 to 6 is currently open.
 chapter
7.1.4.3 Retrieving data with enSuite
b) Test retrieval via the network.
If the communication link to the EK280 is via the optical interface, press the "Disconnect" or the
"Disconnect from all
EK280 and then wait for the "o" top left of on the EK280 display to stop flashing.
Set up the modem communication link from enSuite to the EK280.
( chapter
3.3 Setting up the communication link to EK280 via a network
Once the communication link is set up, you can carry out checks, for instance view certain
parameters. To do this press "Navigation" on the left-hand side of the enSuite window and then
"Parameterize
online" in the bottom of the navigation window, then click on the plus sign next to
"Parameters" and then its subsections.
In enSuite press the "Disconnect" symbol or
Application Manual
"Call time
(p. 64)
devices" icon to terminate the communication link between enSuite and the
"Disconnect from all
windows" open one of the time windows 5 or
(TCP/IP), p. 20)
devices" to end the test retrieval.
107