EK280
7.4.9 FE260 with internal analog modem (PSTN Modem)
Modem adapter board 73016717 V1.2
with a connected telephone cable
La
Lb
La2
Lb2
This interface card is used as an interface for an analog telephone line.
Prerequisites for process described below:
−
The FE260 is connected and configured as described in chapter 7.4.1.
7.4.9.1 Parametrization of the EK280
i
For parameterization of the EK280 you need a connection cable for the optical interface as well
as the enSuite program. enSuite can be downloaded free of charge from the Honeywell website
in the "Software Downloads" section:
www.elster-instromet.com/en/software-downloads
e) Closing the time windows
In order that the parameterization works correctly the time windows 5 and 6 must be closed. To do this:
−
Connect a PC with enSuite installed to the EK280 optical interface using the connection cable.
−
Start enSuite and set up the communication link to the EK280.
( chapter
3.1 Setting up the communication link to the EK280 via optical
−
Select "Navigation" on the left-hand side and then
navigation window.
−
In the top of the device window open the path "Parameters" > "Interfaces" by clicking on the relevant
plus signs, and then select
−
In call windows 5 and 6 set start and end to the same value for each one and then select the
"Transfer changes to device" icon at the top of the enSuite window.
−
Then wait a minute, for any communications activity in progress on the EK280 to be safely stopped.
Application Manual
Fig. 14: INSYS Analog modem module in the FE260
"Call time
windows".
INSYS analog modem
module
interface, p. 19)
"Parameterize
online" at the bottom of the
139