EK280
If you do not need a time window, you can deactivate it by setting the time window start and end to the same
value.
Press the
"Transfer changes to
i
Once a time window has been opened, it takes approx. 1/2 minute until the modem has logged in
into the GSM network for the build-up of a conventional GSM-CSD modem connection.
If the modem has previously been parameterized in accordance with Section 7.1.7.3 for TSC
operation it may take a further 2-3 minutes, until the TSC-Modem has logged on to the TSC
server via the GPRS network and can be called up through it (provided that all APN and
additional TSC. data have been set correctly).
7.1.7.3 Parameterization of the internal ComTSC modem in the EK280
i
For parameterization of the ComTSC modem you will require a USB modem parameterization
cable (ID-No. 730 20 481) for local connection with the modem parameterization interface on the
EK280-CPU board or a GSM/CSD connection and the parameterization program WinPADS200-
EK from version V2.99, which you can download for free from www.elster-instromet.com.
The current parameterization program enSuite does not support the parameterization of a
ComTSC modem!
For the parameterization of the modem TSC function proceed as follows:
Connect your PC/laptop with the parameterization interface X25 on the EK280 CPU board using the
USB parameterization cable pursuant to Retrieving data with enSuite (only for local parameterization
on location of the actual EK280).
Caution, Risk to life!
Always ensure the mains voltage is disconnected before opening the EK280
housing; please ensure it is not turned back on and verify that it is not live.
In WinPADS. depending on the connection, select
connection"
or "Modem":
Application Manual
device" icon at the top of the enSuite window.
Fig. 10: Local connection using the USB parameterization cable
with the EL280 modem parameterizing interface
->
"Action"
"Start connection via"
78
"Local