Modbus Master Via Internal Modem (Rtu_Tcp) - Honeywell EK280 Applications Manual

Volume converter
Hide thumbs Also See for EK280:
Table of Contents

Advertisement

EK280
Designation
Modbus_Master_
Meaning
TaskList_ ...
...MdbNoReg
Disp.
Register
...MdbRegRWMode RW-Mode
...MdbStartAdr
Modbus-Adr.
...MdbNoReg
Disp.
Register
...MdbRegRWMode RW-Mode
...MdbStartAdr
Modbus-Adr.
...MdbNoReg
Disp.
Register
...MdbRegRWMode RW-Mode
Table 12: Extract from the preprogrammed tasks in the Modbus task list
The parameterized trigger event must take place for communication to start. For testing communication, the
parameter 8:D71 can be set with the brief designation "TestC" to 1 on the device under link 8. The link is
then started as a test. Otherwise there will be a wait until the parameterized trigger event takes place.

8.2.7 Modbus master via internal modem (RTU_TCP)

p) Parameterization of the functions of the internal modem is described in  chapter 7.1.
a) Send the parameter file for Modbus parameterization
Send the following parameter file to the EK280 ( chapter
EK280_xvx. - Modbus-Master RTU-TCP int.Modem Connection7 ext. Power supply (*)
q) The following Modbus parameters are preset in this file:
Link 7 is set up for Modbus master communications via the integrated modem. The event type is a
point in time. Telephone book instances 1 and 9 (as alternative) are accessed
Reference is made to instance 6 of Modbus master information
"External supply" is set up as a supply type.
The first 24 tasks on the task list are processed.
A task list is parameterized which writes several Modbus addresses from the standard Modbus table
( chapter 8.1.1) to the client.
Dummy APN data and dummy telephone book parameters. Such data must naturally be overwritten
with the correct parameters to enable communication to take place.
Display
Designation
MMDir
Modbus_Master_AdrDirection
MMTrM
Modbus_Master_TransMode
The * asterisk represents the lower-case letter, used to identify the file version, i.e. "a"
49
Application Manual
Address Value Content
16:8C6
2
2 registers
16:8C7
3
3: Write-FC16
17:8C5
317
6:311_1T.F - Temperature substitute value [°C]
17:8C6
2
2 registers
17:8C7
3
3: Write-FC16
18:8C5
319
14:314N2 - Nitrogen content [%]
18:8C6
2
2 registers
18:8C7
3
3: Write-FC16
Address Value Content
6:7C0
0
6:7C1
2
3.6 Send parameter
file, p. 21):
0: H-Wort erst
2: RTU_TCP
183
49