Honeywell EK280 Applications Manual page 99

Volume converter
Hide thumbs Also See for EK280:
Table of Contents

Advertisement

EK280
b) Sending the parameter file
Send the following parameter file to the EK280 ( chapter
EK280_xvx.. - int. ICE280 (*)
For any further customized settings and tests, press "Navigation" on the left-hand side of the enSuite
window and then
i
All the values listed in enSuite under "Parameters" can be found in the "Serv." display tab of the
EK280 under the same path.
c) Setting the network parameters
You can find the network parameters in enSuite in the parameter tree under "Parameters" > "Interfaces" >
"internal
modem" > "Ethernet" or on the device in the menu
"Ethernet").
Automatic allocation of network address (DHCP):
If the network address is automatically allocated by a DHCP server, the parameter "DHCP" must be
set to "1"
("Use
DHCP").
Set the parameter "Port" to the port number under which this device is to be accessible.
i
You can find the MAC address of the Ethernet interface needed for the DHCP with a dedicated
IP address on the label on the board:
Dedicated network address:
Set the parameter "DHCP" to the value
Then parametrize the following values:
- Device address
- Port ("Port")
- Subnet mask ("SubN")
- Gateway ("Gatew")
13
The "x" stands for the device software version, e.g. "2v2".
The star * stands for a small letter which indicates the version of the file, e.g. "a".
Application Manual
13
"Parameterize
online" at the bottom of the navigation window.
"No
("Own
IP")
3.6 Send parameter
"Service"-"Interfaces"-"internal
DHCP".
97
file, p.21).
modem"-