Honeywell EK280 Applications Manual page 130

Volume converter
Hide thumbs Also See for EK280:
Table of Contents

Advertisement

EK280
One IP address
 Only the computer within the VPN with the specified IP address can access the
ComTCPserv modem, if the firewall in the VPN allows it!
o
Administrator caller ID 1, 2 and
Telephone connections from which a remote parameterization of a ComTCPserv modem is
permitted (only ComTCPserv up toV1.10)
o
Remote
password:
Password for a remote parameterization of the ComTCPserv modem. In the factory, the setting
is set to "0000".
Attention: If you forget the password, no remote parameterization is possible!
o
PIN:
If parameterization is effected via the local interface, and if on the SIM card a PIN is active, this
PIN must be entered. For remote parameterization, a PIN need not be entered, as the modem
requires logging on to the GSM network in any case.
The transfer of the values to the ComTCPserv modemis logged in the trace window of enSuite. The
parameterization has been completed successfully if all parameters have been sent without an error
message and have been acknowledged with "OK" by the modem:
In the event of parameterization through the local parameter interface, the following points must also be
dealt with:
Switch off the power supply to the FE260 and disconnect the parameterization cable from the
FE260.
Set the jumper "Mode" to the "Operation" position (upper position).
Make sure that a GSM antenna is connected and that a SIM card has been inserted into the SIM slot
( chapter 7.4.3) and is unlocked ( chapter 7.4.4).
Reconnect the supply voltage to the FE260.
7.4.6.3 Checking GSM field strength
Before starting a data transfer via the modem, you must ensure that there is adequate reception field
strength.
On the display of the EK280, move the cursor in the tab "Serv." to
GSM & GPRS >
With the cursor over GSM.L, please press the EK280
60 seconds until the field strength percentage is displayed.
Application Manual
3:
GSM.L.
Interfaces >"Terminal interface. >
ENTER
key and wait for approximately 30 to
128