7.3.3 EM260 with Ethernet Adapter

Initial conditions:
The EM260 is connected as described in  chapter
7.3.3.1 Parameterization of the EK280 for operation with an EM260/Ethernet
i
For parameterization of the EK280 you need a connection cable for the optical interface as well
as the enSuite program. enSuite can be downloaded free of charge from the Honeywell website
in the "Software Downloads" section:
www.elster-instromet.com/en/software-downloads
a) Closing the time windows
In order that the parameterization works correctly the time windows 5 and 6 must be closed. Proceed as
described in  chapter
7.3.2.1
b) Sending parameter file
Send the following parameter file to the EK280 ( chapter
EK280_xvx.. - EM260 & int. Ethernet adapter (*)
For any further individual settings and tests required, press "Navigation" on the left-hand side and
then
"Parameterize
i
All the values listed in enSuite under "Parameters" can be found on the "Serv." display tab of the
EK280 under the same path.
i
The EK280 will only work with an EM260 model from year 2009 with a Baud rate of 19200.
EM260 devices before 2009 need to be operated with a Baud rate of 9600.
i
Attention!
Should your Ethernet card already have been parameterized with corresponding network data,
the default settings (e.g. port, IP address, sub net mask) must be deleted from the initialization
string in order to prevent them being accidentally overwritten. You will find the modem
initialization string under "Parameters" > "Interfaces" >
7.3.3.2 Parameterization of the EM260 integrated Ethernet adapter with enSuite
i
For parameterization of the Ethernet adapter in the EM260 for operation with a quantity converter
EK280, a connection cable is required for the optical interface as well as the enSuite program,
which can be downloaded free of charge from www.elster-instromet.com.
15
The "x" stands for the version of software on the device, e.g. "2v2".
The star * stands for a small letter which indicates the version of the file, e.g. "a".
Application Manual
(p. 101).
online" at the bottom of the navigation window.
7.3.1
It is connected but it must not be live.
3.6 Send parameter
15
"Terminal
interface" > "Ethernet".