Press one of the arrow keys  or  until the
flashes.
Press the ENTER key to confirm the value setting. Input can be canceled using the ESC key.
b)
Setting up the source for the output:
When in the corresponding menu press the key until "Sc.O1",
displayed.
Press the ENTER key. ⇒ The actual parameterized value flashes.
Move the cursor to the digits using the  or  arrow keys and update them using the  or  arrow
keys to a value specified in the table.
Sc.O...
Description
02:300_0
Vb
02:301_0
VbD Volume at base conditions (disturbed)
02:302_0
VbT Volume at base conditions total (undisturbed + disturbed)
04:300_0
Vm
04:301_0
VmD Volume at measurement conditions (disturbed)
04:302_0
VmT Volume at measurement conditions total (undisturbed + disturbed)
Press the ENTER key to confirm the value setting. Input can be canceled using the ESC key.
c)
Setting up the cp value for the output:
i
The cp value of an output states how many pulses were emitted per cubic meter. A cp value of
0.1/m3 (0.1 pulses per m3) means that e.g. a pulse is emitted per 10m3.
When in the corresponding menu press the  key until "cp.O1", "cp.O2", "cp.O3" or "cp.O4" is
displayed.
Press the ENTER key. ⇒ The actual parameterized value flashes.
Move the cursor to the digits using the  or  arrow keys and update them using the  or  arrow
keys to the desired cp value for the corresponding output.
Press the ENTER key to confirm the set value. It is possible to abort the entry by pressing the ESC
key.
d)
Setting up period length and pulse duration.
i
Parametrization of the period length and the pulse duration via the EK280 keyboard is only
possible with software version 2.20 or later.
Older software versions may be programmed using enSuite via
"Parameters" and the paths described ( chapter 6.2.1).
Application Manual
Volume at base conditions (undisturbed)
Volume at measurement conditions (undisturbed)
"pulse+"
(Logic active) or
"
Sc.O2",
"Parameterize
"pulse -"
(Logic inactive) text
"
Sc.O3", or
"
Sc.O4" is
online" >