Tcpserv Operation (Gprs Or Umts) - Honeywell EK280 Applications Manual

Volume converter
Hide thumbs Also See for EK280:
Table of Contents

Advertisement

EK280
i
With a field strength below 50% data transfer issues may be encountered. You can remedy this
in the majority of cases with an external antenna, mounted somewhere suitable.
7.1.4.3 Retrieving data with enSuite
a) Opening the test time window for the following test retrievals with enSuite
i
The test time window only needs to be open if none of the time windows 1 to 4 are open.
If the communication link to the EK280 via the optical interface is not set up, it must be created.
( chapter
3.1 Setting up the communication link to the EK280 via optical
Select "Navigation" on the left-hand side of the enSuite window and then
the bottom of the navigation window.
In the top of the device window open the path "Parameters" > "Interfaces" by clicking on the relevant
plus signs, and then select
Click on the "0" value next to
enter a duration in minutes (i.e. 10), for the test time window for the test retrieval to remain open. For
a battery-operated EK280 please do not enter an excessively long duration, as this will adversely
affect the battery life.
Press the
"Transfer changes to
The EK280 is now available via the modem for the duration set.
In enSuite press the "Disconnect" icon or
interface communication link between enSuite and the EK280.
b) Test retrieval via the modem
Set up the modem communication link (=CSD
( chapter
3.2 Setting up the communication link to EK280 via a
Once the communication link is set up, you can carry out checks, for instance view certain
parameters. To do this press "Navigation" on the left-hand side of the enSuite window and then
"Parameterize
online" in the bottom of the navigation window, then click on the plus sign next to
"Parameters" and then its subsections.
In enSuite press the "Disconnect" symbol or

7.1.5 TCPserv operation (GPRS or UMTS)

In this modem operating mode you can access the EK280 via the network (Ethernet, TCP/IP), to which your
retrieval system is connected, i.e., you do not require an additional retrieval system modem. Data transfer is
normally faster than with GSM operation, as explained in  chapter 7.1.4.
CSD=Circuit Switched Data, line switched data service in the case of mobile telephony
5
Application Manual
"internal
modem" (not the plus sign before).
"Test call acceptance
window" in the right-hand side of the window and
device" icon at the top of the enSuite window.
"Disconnect from all
connection) between enSuite and EK280.
5
"Disconnect from all
interface, p. 19)
"Parameterize
devices" to terminate the optical
modem, p. 19)
devices" to end the test retrieval.
64
online" at

Advertisement

Table of Contents
loading

Table of Contents