Mitsubishi Electric FR-A800 Series Instruction Manual page 900

Hide thumbs Also See for FR-A800 Series:
Table of Contents

Advertisement

REVISIONS
*The manual number is given on the bottom left of the back cover.
Revision date
May 2013
Dec. 2013
Mar. 2014
Apr. 2014
Sep. 2014
Mar. 2015
Aug. 2015
Oct. 2016
May 2017
Oct. 2018
Downloaded from
ManualsNet.com
*
Manual number
IB(NA)-0600503ENG-A
First edition
IB(NA)-0600503ENG-B
Added
FR-A840-03250(110K) to FR-A840-06830(280K)
IP55 compatible model
Compatibility with FR-A8NP
SF-PR included (Pr.71 (Pr.450) = "70, 73, 74")
Anti-sway control (Pr.1072 to Pr.1079)
Position control functions added (Pr.1289, Pr.1290, Pr.1292 to Pr.1297)
IB(NA)-0600503ENG-C
Added
Separated converter type
IB(NA)-0600503ENG-D
Added
Motor permissible load level (Pr.607, Pr.608)
FR-A846-00023(0.4K) to FR-A846-00170(5.5K)
IB(NA)-0600503ENG-E
Added
SF-PR heavy duty setting
SF-PR slip amount adjustment mode (Pr.673, Pr.674)
Addition to the power failure time deceleration-to-stop function (Pr.606, X48 signal, Y67 signal, and
compatibility with the separated converter type)
Addition to the self power management function (X94 signal)
Addition to the electronic bypass sequence function (X95 signal and X96 signal)
Pr.1015 Integral stop selection at limited frequency
Pr.1016 PTC thermistor protection detection time
IB(NA)-0600503ENG-F
Added
Second droop control (Pr.679 to Pr.683)
Internal torque limit 2 (Pr.810 = "2")
Pr.1018 Monitor with sign selection
Current position 2 (Pr.430)
Cumulative pulse monitor value clear (Pr.635 to Pr.638)
Compatibility with FR-A8TP, FR-A8APR, and FR-A8AZ
Edited
Availability of the brake sequence function under V/F control
Availability of the anti-sway control under V/F control and Advanced magnetic flux vector control
IB(NA)-0600503ENG-G
Added
FR-A800-GF (CC-Link IE Field Network communication function type)
IB(NA)-0600503ENG-H
Added
Start count monitor (Pr.1410, Pr.411)
Excitation current low-speed scaling factor (Pr.14 = "12 to 15", Pr.85, Pr.86, Pr.565, Pr.566, Pr.617)
Backup/restore function
Input signals (CLRN, JOGF, JOGR)
Output signal (SAFE)
Simple position control by point table (The home position information is retained at servo-OFF.)
(Pr.419 = "10")
MODBUS RTU communication stop bit length selection
Continuous operation at communication error (Pr.502 = "4")
IB(NA)-0600503ENG-J
Added
Load characteristics fault detection (Pr.1480 to Pr.1492)
Droop control using the per-unit speed control reference frequency (Pr.288 (Pr.681) = "20 to 22")
Torque current command limit (Pr.801, Pr.803 = "2")
PID manipulated amount: 0 to 100% (Pr.1015 = "2, 12")
Pr.1348 P/PI control switchover frequency
Pr.1349 Emergency stop operation selection
Operation selection at a communication error (Pr.502 = "11, 12")
Multi-revolution counter monitoring
Edited
Pr.275 setting range: 0 to 300%
IB(NA)-0600503ENG-K
Added
Reset selection / disconnected PU detection / PU stop selection (Pr.75 = "1000 to 1003, 1014 to
1017, 1100 to 1103, 1114 to 1117")
External fault input signal (Pr.178 to Pr.189 = "32")
Error reset operation selection at inverter fault (Pr.349 = "100, 101")
PLC function (Pr.414 = "11, 12", Pr.675)
Pulse monitor selection (Pr.430 = "2000 to 2005, 2012, 2013, 2100 to 2105, 2112, 2113, 3000 to
3005, 3012, 3013, 3100 to 3105, 3112, 3113")
search engine
Revision
899

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents