9.1
For customers replacing the conventional model
with this inverter
9.1.1

Replacement of the FR-A700 series

 Differences and compatibility with the FR-A700 series
Item
Control method
Added functions
Brake transistor (brake
resistor usable)
V/F control
Advanced magnetic
flux vector control
Real sensorless vector
control
Vector control
PM sensorless vector
control
PID control
Automatic restart after
instantaneous power failure
Restart coasting time after
instantaneous power failure
Number of motor poles
V/F control switching
PTC thermistor input
USB connector
Control circuit terminal
block
Terminal response level
PU
Plug-in option
856
9. APPENDIX

9.1 For customers replacing the conventional model with this inverter

Downloaded from
ManualsNet.com
FR-A700
V/F control
Advanced magnetic flux vector control
Real sensorless vector control
Vector control (with plug-in option)
PM sensorless vector control (IPM motor)
Built in for the FR-A720-0.4K to 22K.
Built in for the FR-A740-0.4K to 22K.
400 Hz
120 Hz
120 Hz
120 Hz
300 Hz
Turn the X14 signal ON to enable PID
control.
Turn the CS signal ON to enable restart.
Time period from restoration of power until
the operation is restarted
The V/F switchover (X18) signal is valid
when Pr.81 = "12 to 20" (2 to 10 poles).
Input through terminal AU (The function of
terminal AU is switched by a switch.)
B connector
Removable terminal block (screw type)
The FR-A800's I/O terminals have better response level than the FR-A700's terminals. By setting Pr.289
Inverter output terminal filter and Pr.699 Input terminal filter, the terminal response level can be compatible
with that of FR-A700. Set to approximately 5 to 8 ms and adjust the setting according to the system.
FR-DU07 (4-digit LED)
FR-PU07
Dedicated plug-in options (not interchangeable)
search engine
FR-A800
V/F control
Advanced magnetic flux vector control
Real sensorless vector control
Vector control (with plug-in option / control terminal option)
PM sensorless vector control (IPM motor / SPM motor)
USB host function,
safety stop function,
etc.
Built in for the FR-A820-00046(0.4K) to 01250(22K).
Built in for the FR-A840-00023(0.4K) to 01800(55K).
590 Hz
400 Hz
400 Hz
400 Hz
400 Hz
When the X14 signal is not assigned, just set a value in Pr.128
to enable PID control.
When the X14 signal is assigned, turn the X14 signal ON while
Pr.128 ≠ "0" to enable PID control.
The PID pre-charge function and dancer control are added.
Restart is enabled by turning ON the CS signal, or solely setting
Pr.57 if the CS signal is not assigned to any input terminal.
Time period from occurrence of instantaneous power failure
until the operation is restarted
Pr.81 = "12" (12 poles)
The X18 signal is valid regardless of the Pr.81 setting. (The
Pr.81 settings "14 to 20" are not available.)
Input through terminal 2 (The function of terminal 2 is switched
by the Pr.561 setting.)
Mini B connector
Removable terminal block (spring clamp type)
FR-DU08 (5-digit LED)
FR-LU08 (LCD operation panel)
FR-PU07 (Some functions such as Parameter copy are
unavailable.)
The FR-DU07 is not supported.

Hide quick links: