Frame Number: 160M, 160L, 180M, 180L
Terminal box for cooling fan
Connector (for encoder)
MS3102A20-29P
A
Suction
*1, 2
Direction of
Mark for earthing
cooling fan wind
(grounding)
Earth (ground)
terminal (M8)
W
S
Section AA
Main terminal box
For motor (U, V, W)
U
V
W
B1
B2
G1
G2
For brake (B1, B2)
For thermal protector (G1, G2)
Dimensions table (Unit: mm)
SF-
SF-
SF-
SF-
Frame
V5RU
V5RU
V5RU
V5RU
No.
[]KB
[]K1B
[]K3B
[]K4B
11
7
5
2
160M 140 522.5 198 160 318
15
11
7
3
160L
18
180M
22
15
11
18
15
5
180L
30
7
200L
37, 45 22, 30 18, 22
55
37
30
11, 15 225S 395
NOTE
• Install the motor on the floor and use it with the shaft horizontal.
• Leave an enough clearance between the fan suction port and wall to ensure adequate cooling. Check that a fan blows air from
the opposite load side to the load side.
• The vertical tolerance for the shaft center height is
• The 400 V class motor has "-H" at the end of its model name.
• Since a brake power device is a stand-alone, install it inside the enclosure. (This device should be arranged by the customer.
Refer to the FR-A800 catalog.)
848
8. SPECIFICATIONS
8.4 Outline dimension drawings
Downloaded from
ManualsNet.com
L
R
KL
110
B
KA
D
Main
90
Exhaust
*1
terminal box
A
A
J
F
F
XB
E
N
M
Sliding distance
X
Frame leg viewed
from above
Terminal box for cooling fan
For cooling fan (A, B, C)
Earthing
(grounding)
A
B
C
terminal (M8)
Earthing (grounding)
terminal (M4)
Mass
(kg)
A
B
C
D
E
F
G
H
127
105
8
— —
155 544.5 220 160 318
127
127
8
— —
185
568.5 225.5 180 363 139.5 120.5 8
— —
215
255 587.5 242.5 180 363 139.5 139.5 8
— —
305
644.5 267.5 200 406
159 152.5 11 — —
330
659
277 225 446
178
143
11 — —
search engine
Frame number: 200L, 225S
Connector (for encoder)
MS3102A20-29P
Suction
*2
*1, 2
E
Mark for earthing
Direction of
(grounding)
cooling fan wind
Earth (ground)
terminal (M12)
* indicates an inserting position of a bolt with hex head holes for manual
opening.
Make sure to earth the earth terminal of the flange section as well as
the earth terminal in the terminal box.
Motor
I
J
KA KD KG KL
KP
L
M
ML
50 105 56 115 330 391 845.5 310
50 127 56 115 330 391 889.5 310
50 127 56 139 352 428 920 335
50 146 56 139 352 428 958 335
70 145 90 487
546 1070 390
70 145 90 533
592 1091 428
.
0
-0.5
Terminal box for cooling fan
L
A
R
B
140
φ22
KA
110
Main
terminal box
Exhaust
*1
A
A
J
XB
F
F
E
N
W
S
Section AA
Shaft end
N
X
XB
Z
Q
QK
R
S
T
254
4
108 14.5 110 90
323 42k6
8
298
4
108 14.5 110 90
345 42k6
8
285
4
121 14.5 110 90 351.5 48k6
9
5.5 14
323
4
121 14.5 110 90 370.5 55m6 10
361
4
133 18.5 140 110 425.5 60m6 11
342
4
149 18.5 140 110 432 65m6 11
D
*2
E
M
Sliding distance
X
Frame leg viewed
from above
Terminal screw size
U, V,
A, B,
G1,
B1,
U
W
W
(C)
G2
B2
5
12
M8
M4
M4
M4
5
12
M8
M4
M4
M4
M8
M4
M4
M4
6
16
M8
M4
M4
M4
7
18 M10
M4
M4
M4
7
18 M10
M4
M4
M4