Torque Control Under Real Sensorless Vector Control And Vector Control; Torque Control - Mitsubishi Electric FR-A800 Series Instruction Manual

Hide thumbs Also See for FR-A800 Series:
Table of Contents

Advertisement

5.4
Torque control under Real sensorless vector
control and Vector control
Purpose
Torque command source selection or
torque command value setting
To prevent the motor from
overspeeding
To raise precision of torque control
To stabilize torque detection signal
5.4.1

Torque control

• Under torque control, output torque is controlled to output the torque as commanded.
• Motor rotation speed is steady when the motor output torque and load torque are balanced.
Thus, motor speed during torque control is determined by the load.
• Under torque control, motor speed accelerates so motor output torque does not exceed motor load.
In order to prevent the motor from overspeeding, set a speed limit.
(Speed control is performed instead of torque control during speed limit.)
• If speed limit is not set, speed limit value setting is regarded as 0 Hz and torque control is not enabled.
272
5. PARAMETERS

5.4 Torque control under Real sensorless vector control and Vector control

Downloaded from
ManualsNet.com
Torque command
Speed limit
Torque control gain
adjustment
Torque detection
filter
search engine
Parameter to set
P.D400 to P.D403, P.G210,
Pr.801, Pr.803 to Pr.806,
P.H704
Pr.1114
P.H410 to P.H412, P.H414
Pr.807 to Pr.809, Pr.1113
P.G213, P.G214, P.G313,
Pr.824, Pr.825, Pr.834,
P.G314
Pr.835
P.G216, P.G316
Pr.827, Pr.837
Refer
to page
283
287
294
332

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents