Mitsubishi Electric FR-A800 Series Instruction Manual page 207

Hide thumbs Also See for FR-A800 Series:
Table of Contents

Advertisement

Pr. group
Pr.
H721
817
H730
874
H800
374
H881
690
 M: Monitoring and its output
signal
Parameters for the settings regarding the monitoring to check
the inverter's operating status and the output signals for the
monitoring.
Pr. group
Pr.
M000
37
M001
505
M002
144
M020
170
M021
563
M022
268
M023
891
M030
171
M031
564
M040
55
M041
56
M042
866
M043
241
M044
290
M045
1018
M050
1106
M051
1107
M052
1108
M060
663
M100
52
M101
774
M102
775
M103
776
M104
992
M200
892
M201
893
M202
894
M203
895
M204
896
206
5. PARAMETERS
5.1 Parameter list
Downloaded from
ManualsNet.com
Name
Torque limit level during
deceleration
OLT level setting
Overspeed detection level
Deceleration check time
Name
Speed display
Speed setting reference
Speed setting switchover
Watt-hour meter clear
Energization time carrying-
over times
Monitor decimal digits
selection
Cumulative power monitor
digit shifted times
Operation hour meter clear
Operating time carrying-over
times
Frequency monitoring
reference
Current monitoring reference
Torque monitoring reference
Analog input display unit
switchover
Monitor negative output
selection
Monitor with sign selection
Torque monitor filter
Running speed monitor filter
Excitation current monitor
filter
Control circuit temperature
signal output level
Operation panel main monitor
selection
Operation panel monitor
selection 1
Operation panel monitor
selection 2
Operation panel monitor
selection 3
Operation panel setting dial
push monitor selection
Load factor
Energy saving monitor
reference (motor capacity)
Control selection during
commercial power-supply
operation
Power saving rate reference
value
Power unit cost
search engine
Refer
Pr. group
Pr.
to page
245
M205
897
245
M206
898
443
270
M207
899
M300
54
M301
158
C0
M310
*2
(900)
C1
M320
*2
(901)
M321
867
Refer
to page
C8
M330
*2
444
(930)
444
C9
M331
*2
444
(930)
446
C10
M332
*2
(931)
446
C11
M333
*2
(931)
446
M334
869
446,
467
M400
190
446
M401
191
M402
192
446
M403
193
457
M404
194
457
M405
195
457
M406
196
505
*5*6
M410
313
446,
*5*6
457
M411
314
446
*5*6
M412
315
446
*5
M413
316
446
*5
M414
317
446
*5
M415
318
*5
M416
319
494
*5
M420
320
446
*5
M421
321
*5
M422
322
446
M430
157
446
M431
289
446
M433
166
457,
M440
870
446
M441
41
467
M442
42
467
M443
43
M444
50
467
M445
116
467
M446
865
467
M460
150
Name
Power saving monitor average
time
Power saving cumulative
monitor clear
Operation time rate (estimated
value)
FM/CA terminal function
selection
AM terminal function selection
FM/CA terminal calibration
AM terminal calibration
AM output filter
Current output bias signal
Current output bias current
Current output gain signal
Current output gain current
Current output filter
RUN terminal function
selection
SU terminal function selection
IPF terminal function selection
OL terminal function selection
FU terminal function selection
ABC1 terminal function
selection
ABC2 terminal function
selection
DO0 output selection
DO1 output selection
DO2 output selection
DO3 output selection
DO4 output selection
DO5 output selection
DO6 output selection
RA1 output selection
RA2 output selection
RA3 output selection
OL signal output timer
Inverter output terminal filter
Output current detection
signal retention time
Speed detection hysteresis
Up-to-frequency sensitivity
Output frequency detection
Output frequency detection for
reverse rotation
Second output frequency
detection
Third output frequency
detection
Low speed detection
Output current detection level
Refer
to page
467
467
467
457
457
463
463
463
463
463
463
463
463
473
473
473
473
473
473
473
473
473
473
473
473
473
473
473
473
473
245,
431
473
487
484
484
484
484
484
488,
484
484
487

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents