 Selecting the command interface in the Network operation mode (Pr.338,
Pr.339)
• Selecting a command interface is required for the following two types of commands: the operation command using the start
signals and the signals related to the inverter function selection, and the speed command using signals related to the
frequency setting.
• The following table shows the command interface for each function in the Network operation mode, determined by the
parameter settings: an external terminal or a communication interface (RS-485 terminals or communication option).
Pr.338 Communication operation command source
Pr.339 Communication speed command source
Frequency setting through communication
Terminal 2
Terminal 4
Terminal 1
Low-speed operation command/Remote setting
*1
RL
(setting clear)/Stop-on-contact selection 0
Middle-speed operation command/Remote setting
*1
RM
(deceleration)
High-speed operation command/ Remote setting
*1
RH
(acceleration)
Second function selection/ Stop-on-contact
*1
RT
selection 1
*1
Terminal 4 input selection
AU
*1
Jog operation selection
JOG
Selection of automatic restart after instantaneous
*1
CS
power failure / flying start
*1
External thermal relay input
OH
*1
15-speed selection
REX
*1
Third function selection
X9
*1
Inverter run enable
X10
FR-HC2/FR-CC2 connection, instantaneous
*1
X11
power failure detection
*1
PU operation external interlock
X12
*1
External DC injection brake operation start
X13
*1
PID control valid
X14
*1
Brake opening completion
BRI
*1
PU/External operation switchover
X16
Load pattern selection forward/reverse rotation
*1
X17
boost
*1
V/F switchover
X18
*1
Load torque high-speed frequency
X19
*1
S-pattern acceleration/deceleration C switchover
X20
*1
Orientation command
X22
*1
Pre-excitation/servo ON
LX
Output stop
*1
MRS
PU operation interlock
STP
Start self-holding selection
*1
(STOP)
*1
Control mode switchover
MC
*1
Torque limit selection
TL
*1
Start-time tuning start external input
X28
*1
External fault input
X32
*1
Traverse function selection
X37
404
5. PARAMETERS
5.9 (D) Operation command and frequency command
Downloaded from
ManualsNet.com
search engine
0: NET
1: EXT
0:
1:
2:
0:
NET
EXT
EXT
NET
EXT
NET
NET
NET
EXT
EXT
EXT
EXT
Compensation
NET
EXT
NET
EXT
NET
EXT
NET
EXT
NET
EXT
NET
EXT
NET
EXT
Combined
Combined
EXT
EXT or NET
EXT
EXT
NET
EXT
NET
EXT
NET
EXT
EXT
EXT
EXT
NET
EXT
NET
EXT
NET
EXT
NET
EXT
EXT
NET
EXT
NET
EXT
NET
EXT
NET
EXT
NET
EXT
NET
EXT
Combined
EXT
EXT
EXT
NET
EXT
NET
EXT
NET
EXT
EXT
NET
EXT
Remarks
1:
2:
EXT
NET
Pr.59 = "0" (multi-speed),
Pr.59 ≠ "0" (remote), Pr.270
="1, 3, 11, or 13" (stop-on-
contact)
Pr.270 ="1, 3, 11, or 13" (stop-
on-contact)
EXT or NET is selected
according to the setting in
*2
Pr.162.
Pr.59 ="0" (multi-speed)
Pr.79 ≠ "7"
Pr.79 = "7".
When X12 signal is not
assigned.