Mitsubishi Electric FR-A800 Series Instruction Manual page 553

Hide thumbs Also See for FR-A800 Series:
Table of Contents

Advertisement

Pr.
Name
90
Motor constant (R1)
C120
92
Motor constant (L1)/d-
C122
axis inductance (Ld)
93
Motor constant (L2)/q-
C123
axis inductance (Lq)
859
Torque current/Rated
C126
PM motor current
706
Induced voltage
C130
constant (phi f)
Motor induced voltage
1412
constant (phi f)
C135
exponent
711
Motor Ld decay ratio
C131
712
Motor Lq decay ratio
C132
717
Starting resistance
C182
tuning compensation
Starting magnetic pole
721
position detection
C185
pulse width
725
Motor protection
C133
current level
Lq tuning target
1002
current adjustment
C150
coefficient
450
Second applied motor
C200
453
Second motor capacity 9999
C201
454
Number of second
C202
motor poles
51
Second electronic
C203
thermal O/L relay
456
Rated second motor
C204
voltage
457
Rated second motor
C205
frequency
743
Second motor
C206
maximum frequency
744
Second motor inertia
C207
(integer)
745
Second motor inertia
C208
(exponent)
552
5. PARAMETERS
5.13 (C) Motor constant parameters
Downloaded from
ManualsNet.com
Initial
Setting range
value
0 to 50 Ω, 9999
9999
0 to 400 mΩ, 9999
0 to 500 mH, 9999
9999
0 to 50 mH, 9999
0 to 500 mH, 9999
9999
0 to 50 mH, 9999
0 to 500 A, 9999
9999
0 to 3600 A, 9999
0 to 5000 mV (rad/s)
9999
9999
0 to 2
9999
9999
9999
0 to 100%, 9999
9999
0 to 100%, 9999
9999
0 to 200%, 9999
0 to 6000 μs, 10000 to
9999
16000 μs, 9999
100 to 500%
9999
9999
50 to 150%
9999
9999
0, 1, 3 to 6, 13 to 16, 20,
23, 24, 30, 33, 34, 40, 43,
44, 50, 53, 54, 70, 73, 74,
330, 333, 334, 8090,
9999
8093, 8094, 9090, 9093,
9094
9999
0.4 to 55 kW
0 to 3600 kW
9999
2, 4, 6, 8, 10, 12
9999
9999
0 to 500 A
9999
0 to 3600 A
9999
200 V/ 400
0 to 1000 V
*4
V
10 to 400 Hz
9999
9999
0 to 400 Hz
9999
9999
9999
10 to 999, 9999
9999
0 to 7, 9999
search engine
*2*5
*3*5
*2*5
Tuning data (The value measured by offline auto tuning is
automatically set.)
*3*5
9999: The MM-CF constant is used when the IPM motor MM-
*2*5
CF is selected, and the inverter internal data is used when a PM
*3*5
motor other than MM-CF is selected.
*2*5
*3*5
*5
Set this parameter according to the PM motor specifications.
The value calculated from the parameter setting for motor
constant is used.
Set the exponent n when the induced voltage constant phi f
(Pr.706) is multiplied by 10
No exponent setting
Tuning data (The value measured by offline auto tuning is
automatically set.)
9999: The MM-CF constant is used when the IPM motor MM-
CF is selected, and the inverter internal data is used when a PM
motor other than MM-CF is selected.
Set the maximum current (OCT) level of the motor.
The MM-CF constant is used when the IPM motor MM-CF is
selected, and 200% when a PM motor other than MM-CF is
selected.
Adjust the target current during tuning.
100%
Set this parameter when using the second motor
(the same specifications as Pr.71).
The function is disabled.
*2
Set the capacity of the second motor.
*3
V/F control
Set the number of poles of the second motor.
V/F control
*2
Set the rated current of the second motor.
*3
The second electronic thermal O/L relay is disabled.
Set the rated voltage (V) of the second motor.
Set the rated frequency (Hz) of the second motor.
The MM-CF constant is used when the IPM motor MM-CF is
selected for the second motor, and the inverter internal data is
used when a PM motor other than MM-CF is selected. Use the
correct setting according to the motor specification.
Set the permissible speed (frequency) of the second motor.
The MM-CF motor maximum frequency is used when the MM-
CF is selected, and Pr.457 setting is used when a motor other
than MM-CF is selected.
Set the inertia of the second motor.
9999: The MM-CF inertia is used for the IPM motor MM-CF.
Description
n
.