Start Signal Operation Selection / Stop Selection - Mitsubishi Electric FR-A800 Series Instruction Manual

Hide thumbs Also See for FR-A800 Series:
Table of Contents

Advertisement

Parameters referred to
Pr.10 DC injection brake operation frequency, Pr.11 DC injection brake operation time, Pr.12 DC injection brake operation
Pr.13 Starting
frequencypage

5.16.10 Start signal operation selection / stop selection

Select the stopping method (deceleration stop or coasting) at turn-OFF of the start signal.
Coasting can be selected for the cases such that the motor is stopped with a mechanical brake at turn-OFF of the start signal.
The operation of the start signal (STF/STR) can be selected.
Pr.
Name
250
Stop
G106
selection
 Stop selection
 To decelerate the motor to a stop
• Set Pr.250 = "9999 (initial value) or 8888".
• The motor is decelerated to a stop when the start signal (STF/STR) is turned OFF.
 To coast the motor to a stop
• Set the time required to shut off the output after the start signal is turned OFF in Pr.250. When "1000 to 1100" is set, output
is shut off after a lapse of the (Pr.250 - 1000) seconds.
• The output is shut off after a lapse of the setting time of Pr.250 when the start signal is turned OFF. Motor coasts to a stop.
• The RUN signal is turned OFF when the output is shut off.
722
5. PARAMETERS
5.16 (G) Control parameters
Downloaded from
ManualsNet.com
381,
page 382
Initial value
Setting range
0 to 100 s
1000 to 1100 s
9999
9999
8888
Start
ON
signal
RUN
signal
Start signal
RUN signal
search engine
Start signal (STF/STR)
STF signal: Forward rotation start
STR signal: Reverse rotation start
STF signal: Start signal
STR signal: Forward/reverse rotation
signal
STF signal: Forward rotation start
STR signal: Reverse rotation start
STF signal: Start signal
STR signal: Forward/reverse rotation
signal
Deceleration starts
when start signal turns OFF
Deceleration time
(Time set in Pr. 8, etc.)
DC brake
Time
OFF
OFF
ON
Output is shut off when
set time elapses after
start signal turns OFF
Pr.250
Motor coasts to stop
OFF
ON
OFF
ON
voltagepage 715
Description
Stop operation
The motor coasts to a stop after a
lapse of the setting time when the
start signal is turned OFF.
The motor coasts to a stop after a
lapse of the (Pr.250 - 1000)
seconds when the start signal is
turned OFF.
The motor is decelerated to a stop
when the start signal is turned OFF.
Time