After making sure that the wiring is correct and secure, set "2 or 102" in Pr.30 Regenerative function selection. (Refer to
page
724.)
MCCB MC
Fuse
Fuse
Power
supply
Fuse
*1
Never connect the power supply to terminals R/L1, S/L2, and T/L3 on the inverter. Doing so will damage the inverter and the converter.
*2
Instead of connecting the terminals to the AC power supply, the control circuit can be powered by connecting terminal R1/L11 to terminal P/+ (P3)
and terminal S1/L21 to terminal N/-. In this case, do not connect the terminals to the AC power supply. Doing so will damage the inverter.
*3
Terminal P3 is equipped in the FR-A820-00770(15K) to 01250(22K), and FR-A840-00470(18.5K) to 01800(55K). When connecting multiple
inverters in parallel, always use either terminal P/+ or P3 for the connection. (Do not use terminals P/+ and P3 together.)
*4
When the FR-XC is connected, the jumper across terminals P/+ and P1 does not affect the function. (The FR-XC can be connected with the
jumper connected.) Refer to
*5
Connect between the inverter terminal P/+ and the converter terminal P/+ and between the inverter terminal N/- and the converter terminal N/-
for polarity consistency.
Connecting opposite polarity of terminals P/+ and N/- will damage the converter and the inverter.
*6
Confirm the correct phase sequence of three-phase current to connect between the reactor and the converter, and between the power supply
and terminals R/L1, S/L2, and T/L3.
Incorrect connection will damage the converter.
*7
Be sure to connect the power supply and terminals R/L1, S/L2, and T/L3 of the converter. Operating the inverter without connecting them will
damage the converter.
*8
Assign the X10 signal to any of the input terminals.
*9
To use separate power supply for the control circuit, remove each jumper at terminal R1/L11 and terminal S1/L21.
*10 Install UL listed fuses on the input side of the reactor to meet the UL/cUL standards (refer to the FR-XC Instruction Manual for information about
the fuse).
106
2. INSTALLATION AND WIRING
2.10 Connection of stand-alone option units
Downloaded from
ManualsNet.com
FR-XCL
*6*11
R/L1
R2/L12
R2/L12
*10
S/L2
S2/L22
S2/L22
*10
T/L3
T2/L32
T2/L32
*10
R/L1
*6*7
S/L2
T/L3
*9
R1/L11
S1/L21
RES
SOF
LOH
SD
page 55
for the jumper connection status in the initial setting.)
search engine
FR-XC
P4
*12
Junction terminal
P/+
Fuse
N/-
Fuse
RYB
RSO
SE
C
B
A
Junction terminal
Fuse
Fuse
Junction terminal
Fuse
Fuse
Inverter
U
*1
R/L1
V
S/L2
IM
M
W
T/L3
R1/L11
*2
S1/L21
P/+(P3)
*3*4*5
P1
N/-
X10(MRS)
*8
RES
SD
Inverter
*1
U
R/L1
V
S/L2
IM
M
W
T/L3
R1/L11
*2
S1/L21
P/+(P3)
*3*4*5
P1
N/-
X10(MRS)
*8
RES
SD
Inverter
*1
U
R/L1
V
S/L2
IM
M
W
T/L3
R1/L11
*2
S1/L21
P/+(P3)
*3*4*5
P1
N/-
X10(MRS)
*8
RES
SD