For the ND rating
• 200 V class (220 V input power supply, without a power factor improving AC or DC reactor)
Applicable
Terminal
inverter model
FR-A820-[]
00046(0.4K) to
M4
00167(2.2K)
00250(3.7K)
M4
00340(5.5K)
M5 (M4)
00490(7.5K)
M5 (M4)
00630(11K)
M5
00770(15K)
M6
00930(18.5K)
M8 (M6)
01250(22K)
M8 (M6)
01540(30K)
M8 (M6)
01870(37K)
M10 (M8) 26.5
02330(45K)
M10 (M8) 26.5
03160(55K)
M12 (M8) 46
• 200 V class (220 V input power supply, with a power factor improving AC or DC reactor)
Applicable
Terminal
inverter model
FR-A820-[]
00046(0.4K) to
M4
00167(2.2K)
00250(3.7K)
M4
00340(5.5K)
M5 (M4)
00490(7.5K)
M5 (M4)
00630(11K)
M5
00770(15K)
M6
00930(18.5K)
M8 (M6)
01250(22K)
M8 (M6)
01540(30K)
M8 (M6)
01870(37K)
M10 (M8) 26.5
02330(45K)
M10 (M8) 26.5
03160(55K)
M12 (M8) 46
03800(75K)
M12 (M8) 46
04750(90K)
M12 (M8) 46
• 400 V class (440 V input power supply, without a power factor improving AC or DC reactor)
Applicable
Terminal
inverter model
screw
FR-A840-[]
size
00023(0.4K)
to
M4
00126(3.7K)
00170(5.5K)
M4
00250(7.5K)
M4
00310(11K)
M5
00380(15K)
M5
00470(18.5K)
M6
00620(22K)
M6
00770(30K)
M6
00930(37K)
M8
01160(45K)
M8
01800(55K)
M8
58
2. INSTALLATION AND WIRING
2.5 Main circuit terminals
Downloaded from
ManualsNet.com
Crimp terminal
Tightening
screw
torque
R/L1,
*4
size
(N·m)
S/L2, T/
U, V, W
L3
1.5
2-4
2-4
1.5
5.5-4
5.5-4
2.5
5.5-5
5.5-5
2.5
14-5
8-5
2.5
14-5
14-5
4.4
22-6
22-6
7.8
38-8
22-8
7.8
38-8
38-8
7.8
60-8
60-8
80-10
60-10
100-10 100-10 100
100-12 100-12 100
Crimp terminal
Tightening
screw
torque
R/L1,
*4
size
(N·m)
S/L2, T/
U, V, W
L3
1.5
2-4
2-4
1.5
5.5-4
5.5-4
2.5
5.5-5
5.5-5
2.5
14-5
8-5
2.5
14-5
14-5
4.4
22-6
22-6
7.8
22-8
22-8
7.8
38-8
38-8
7.8
60-8
60-8
60-10
60-10
100-10 100-10 100
100-12 100-12 100
150-12 150-12 125
150-12 150-12 150
Crimp terminal
Tightening
torque
*4
(N·m)
R/L1, S/
U, V, W
L2, T/L3
1.5
2-4
2-4
1.5
2-4
2-4
1.5
5.5-4
5.5-4
2.5
5.5-5
5.5-5
2.5
8-5
5.5-5
4.4
14-6
8-6
4.4
14-6
14-6
4.4
22-6
22-6
7.8
22-8
22-8
7.8
38-8
38-8
7.8
60-8
60-8
search engine
2
*1
HIV cables, etc. (mm
)
R/L1,
Earthing
U, V,
P/+,
S/L2,
(grounding)
W
P1
T/L3
cable
2
2
2
2
3.5
3.5
3.5
3.5
5.5
5.5
5.5
5.5
14
8
14
5.5
14
14
14
8
22
22
22
14
38
22
38
14
38
38
38
22
60
60
60
22
80
60
80
22
100
100
38
100
100
38
2
*1
HIV cables, etc. (mm
)
R/L1,
Earthing
U, V,
S/L2,
P/+, P1
(grounding)
W
T/L3
cable
2
2
2
2
3.5
3.5
3.5
3.5
5.5
5.5
5.5
5.5
14
8
14
5.5
14
14
14
8
22
22
22
14
22
22
38
14
38
38
38
22
60
60
60
22
60
60
80
22
100
100
38
100
100
38
125
125
38
150
150
38
2
*1
HIV cables, etc. (mm
)
R/L1,
Earthing
U, V,
P/+,
S/L2,
(grounding)
W
P1
T/L3
cable
2
2
2
2
2
2
3.5
3.5
3.5
3.5
3.5
3.5
5.5
5.5
5.5
5.5
8
5.5
8
5.5
14
8
14
8
14
14
22
14
22
22
22
14
22
22
22
14
38
38
38
22
60
60
60
22
Cable gauge
*2
AWG/MCM
PVC cables, etc. (mm
R/L1,
R/L1,
U, V,
U, V,
S/L2,
S/L2,
W
W
T/L3
T/L3
14
14
2.5
2.5
12
12
4
4
10
10
6
6
6
8
16
10
6
6
16
16
4
4
25
25
2
4
35
25
2
2
35
35
1/0
1/0
50
50
3/0
1/0
70
70
4/0
4/0
95
95
4/0
4/0
95
95
Cable gauge
*2
AWG/MCM
PVC cables, etc. (mm
R/L1,
R/L1,
U, V,
U, V,
S/L2,
S/L2,
W
W
T/L3
T/L3
14
14
2.5
2.5
12
12
4
4
10
10
6
6
8
8
10
10
6
6
16
16
4
4
25
25
4
4
25
25
2
2
35
35
1/0
1/0
50
50
1/0
1/0
70
70
4/0
4/0
95
95
4/0
4/0
95
95
250
250
120
120
300
300
150
150
Cable gauge
*2
AWG/MCM
PVC cables, etc. (mm
R/L1,
R/L1,
U, V,
U, V,
S/L2,
S/L2,
W
W
T/L3
T/L3
14
14
2.5
2.5
12
14
2.5
2.5
12
12
4
4
10
10
6
6
8
10
10
6
6
8
16
10
6
6
16
16
4
4
25
25
4
4
25
25
1
2
50
50
1/0
1/0
50
50
2
*3
)
Earthing
(grounding)
cable
2.5
4
6
16
16
16
25
25
25
35
50
50
2
*3
)
Earthing
(grounding)
cable
2.5
4
6
10
16
16
16
25
25
35
50
50
—
—
2
*3
)
Earthing
(grounding)
cable
2.5
4
4
10
10
16
16
16
16
25
25