Mitsubishi Electric FR-A800 Series Instruction Manual page 391

Hide thumbs Also See for FR-A800 Series:
Table of Contents

Advertisement

Pr.79
setting
External/PU switchover mode.
0 (initial
The inverter operation mode can be switched between PU and External by pressing
value)
At power ON, the inverter is in the External operation mode.
1
Fixed at PU operation
mode.
Fixed at External operation
mode.
However, the inverter
2
operation mode can also be
changed to the Network
operation mode.
External/PU combined
3
operation mode 1
External/PU combined
4
operation mode 2
Operation mode switchover during operation.
6
Switching from among the PU, External, and NET operation modes can be performed during
operation.
External operation mode (PU operation interlock).
X12 signal ON: Switchover to PU operation mode enabled (signal is OFF during External
7
operation).
X12 signal OFF: Switchover to PU operation mode disabled.
*1
The following is the frequency commands listed in descending order of priority when "3" is set in Pr.79: Multi-speed setting function (RL/RM/RH/
REX signal) > PID control (X14 signal) > terminal 4 analog input (AU signal) > digital input from the operation panel.
 Operation mode basics
• The operation mode specifies the source of the start command and the frequency command for the inverter.
390
5. PARAMETERS
5.9 (D) Operation command and frequency command
Downloaded from
ManualsNet.com
Operation mode
Frequency command
Sent from the operation panel
or parameter unit.
Sent using external signals
(input via terminal 2 or 4, using
the JOG signal, using the
multi-speed setting function,
etc.).
Sent from the operation panel
or parameter unit or sent using
external signals (input using
the multi-speed setting
function or via terminal 4).
Sent using external signals
(input via terminal 2 or 4, using
the JOG signal, using the
multi-speed setting function,
etc.).
search engine
Description
Start command
Sent by pressing
on operation panel or
parameter unit.
Sent using external signals (via
terminal STF or STR).
Sent using external signals (via
terminal STF or STR).
*1
Sent by pressing
on operation panel or
parameter unit.
LED indicator
Refer to
: OFF
page
: ON
PU operation
mode
External operation
mode
394
.
NET operation
mode
PU operation
mode
or
394
External operation
mode
394
NET operation
mode
394
External/PU
combined
operation mode
or
395
PU operation
mode
395
External operation
mode
NET operation
395
mode