Mitsubishi Electric FR-A800 Series Instruction Manual page 205

Hide thumbs Also See for FR-A800 Series:
Table of Contents

Advertisement

Pr. group
Pr.
F040
1103
F070
791
F071
792
F100
29
F101
59
F102
13
F103
571
F200
140
F201
141
F202
142
F203
143
F300
380
F301
381
F302
382
F303
383
F400
516
F401
517
F402
518
F403
519
F500
292
F510
61
F511
62
F512
63
F513
293
F520
64
 D: Parameters for the setting of
operation command and
frequency command
Parameters for setting the command source to the inverter,
and the motor driving frequency and torque.
Pr. group
Pr.
D000
79
D001
340
D010
338
204
5. PARAMETERS
5.1 Parameter list
Downloaded from
ManualsNet.com
Name
Deceleration time at
emergency stop
Acceleration time in low-speed
range
Deceleration time in low-speed
range
Acceleration/deceleration
pattern selection
Remote function selection
Starting frequency
Holding time at a start
Backlash acceleration
stopping frequency
Backlash acceleration
stopping time
Backlash deceleration
stopping frequency
Backlash deceleration
stopping time
Acceleration S-pattern 1
Deceleration S-pattern 1
Acceleration S-pattern 2
Deceleration S-pattern 2
S-pattern time at a start of
acceleration
S-pattern time at a completion
of acceleration
S-pattern time at a start of
deceleration
S-pattern time at a completion
of deceleration
Automatic acceleration/
deceleration
Reference current
Reference value at
acceleration
Reference value at
deceleration
Acceleration/deceleration
separate selection
Starting frequency for elevator
mode
Name
Operation mode
selection
Simple
Simple
Simple
Communication startup mode
selection
Communication operation
command source
search engine
Refer
Pr. group
Pr.
to page
367
D011
339
367
D012
550
367
D013
551
372
D020
78
377
D030
811
381,
382
D100
291
381
D101
384
372
D110
385
372
D111
386
372
*1
D120
432
372
*1
D121
433
372
D200
15
372
372
D300
28
372
D301
4
372
372
D302
5
372
D303
6
372
D304 to
24 to 27
D307
384,
D308 to
232 to
387,
D315
239
572
384,
D400
804
387
D401
805
384
D402
806
384
D403
1114
384
 H: Protective function parameter
387
Parameters to protect the motor and the inverter.
Pr. group
Pr.
H000
9
H001
600
H002
601
Refer
to page
H003
602
389,
398
H004
603
398
H005
604
400
H006
607
Name
Communication speed
command source
NET mode operation command
source selection
PU mode operation command
source selection
Reverse rotation prevention
selection
Set resolution switchover
Pulse train I/O selection
Input pulse division scaling
factor
Frequency for zero input pulse
Frequency for maximum input
pulse
Pulse train torque command
bias
Pulse train torque command
gain
Jog frequency
Multi-speed input
compensation selection
Multi-speed setting (high
speed)
Simple
Simple
Simple
Multi-speed setting (middle
speed)
Simple
Simple
Simple
Multi-speed setting (low
Simple
Simple
Simple
speed)
Multi-speed setting (speed 4 to
speed 7)
Multi-speed setting (speed 8 to
speed 15)
Torque command source
selection
Torque command value (RAM)
Torque command value (RAM,
EEPROM)
Torque command reverse
selection
Name
Electronic thermal O/L
relay
Simple
Simple
Simple
First free thermal reduction
frequency 1
First free thermal reduction
ratio 1
First free thermal reduction
frequency 2
First free thermal reduction
ratio 2
First free thermal reduction
frequency 3
Motor permissible load level
Refer
to page
400
400
400
406
245,
444
406,
457
406
406
406
283
283
410
411
411
411
411
411
411
283
283
283
283
Refer
to page
415,
532,
551
415
415
415
415
415
415

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents