Mitsubishi Electric FR-A800 Series Instruction Manual page 347

Hide thumbs Also See for FR-A800 Series:
Table of Contents

Advertisement

Pr.
(Multi-speed setting high-speed, middle-speed,
4 to 6
low-speed)
22
Stall prevention operation level
24 to 27
(Multi-speed setting speed 4 to speed 7)
52
Operation panel main monitor selection
54
FM/CA terminal function selection
55
Frequency monitoring reference
56
Current monitoring reference
*1
PWM frequency selection
72
Reset selection/Disconnected PU detection/PU
75
stop selection
77
Parameter write selection
*2
Operation mode selection
79
129
PID proportional band
130
PID integral time
133
PID action set point
134
PID differential time
158
AM terminal function selection
160
User group read selection
232 to 239
(Multi-speed setting speed 8 to speed 15)
*1
Soft-PWM operation selection
240
241
Analog input display unit switchover
268
Monitor decimal digits selection
271
High-speed setting maximum current
272
Middle-speed setting minimum current
273
Current averaging range
274
Current averaging filter time constant
Stop-on contact excitation current low-speed
*1
275
scaling factor
290
Monitor negative output selection
295
Frequency change increment amount setting
296, 297
(Password setting)
306
Analog output signal selection
310
Analog meter voltage output selection
*2
Communication startup mode selection
340
345, 346
(DeviceNet communication)
416, 417
(PLC)
434, 435
(CC-Link communication)
496, 497
(Remote output)
498
PLC function flash memory clear
*2
NET mode operation command source selection
550
*1
Writing during operation is enabled in PU operation mode, but disabled in External operation mode.
*2
Writing during operation is disabled. To change the parameter setting value, stop the operation.
 Parameter write disabled (Pr.77 = "1")
• Parameter write, Parameter clear, and All parameter clear are disabled. (Parameter read is enabled.)
• The following parameters can be written even if Pr.77 = "1".
Pr.
22
Stall prevention operation level
Reset selection/Disconnected PU detection/PU stop
75
selection
77
Parameter write selection
*1
Operation mode selection
79
160
User group read selection
296
Password lock level
297
Password lock/unlock
*1
Writing during operation is disabled. To change the parameter setting value, stop the operation.
346
5. PARAMETERS
5.7 (E) Environment setting parameters
Downloaded from
ManualsNet.com
Name
Name
search engine
Pr.
*2
PU mode operation command source selection
551
555 to 557
(Current average value monitoring)
656 to 659
(Analog remote output)
663
Control circuit temperature signal output level
675
User parameter auto storage function selection
750, 751
Motor thermistor interface
759
PID unit selection
774 to 776
(PU/DU monitor selection)
805
Torque command value (RAM)
806
Torque command value (RAM, EEPROM)
838
DA1 terminal function selection
866
Torque monitoring reference
888, 889
(Free parameter)
891 to 899
(Energy saving monitoring)
C0 (900)
FM/CA terminal calibration
C1 (901)
AM terminal calibration
C8 (930)
Current output bias signal
C9 (930)
Current output bias current
C10 (931)
Current output gain signal
C11 (931)
Current output gain current
990
PU buzzer control
991
PU contrast adjustment
992
Operation panel setting dial push monitor selection
997
Fault initiation
*2
PM parameter initialization
998
*2
Automatic parameter setting
999
1000
Direct setting selection
1006
Clock (year)
1007
Clock (month, day)
1008
Clock (hour, minute)
1018
Monitor with sign selection
1019
Analog meter voltage negative output selection
1048
Display-off waiting time
1142
Second PID unit selection
1150 to 1199
(PLC function user parameters)
1283
Home position return speed
1284
Home position return shifting speed
Pr.
345, 346
(DeviceNet communication)
496, 497
(Remote output)
656 to 659 (Analog remote output)
805
Torque command value (RAM)
806
Torque command value (RAM, EEPROM)
997
Fault initiation
Name
Name