 Changing the motor constants
• The motor constants can be set directly when the motor constants are known in advance, or by using the data measured
during offline auto tuning.
• According to the Pr.71 (Pr.450) setting, the range of the motor constant parameter setting values and units can be
changed. The changed settings are stored in the EEPROM as the motor constant parameters.
 Changing the motor constants (when setting the Pr.92 and Pr.93 motor
constants in units of mH)
• Set Pr.71 as follows.
Mitsubishi Electric standard motor
Mitsubishi Electric high-efficiency motor
Mitsubishi Electric constant-torque motor
Mitsubishi Electric high-performance
energy-saving motor
Vector control dedicated motor
• Use the following formula to find the Pr.94 setting value and set a desired value as the motor constant parameter.
The setting value of Pr.94 = (1 -
R1
I1
V
M
Equivalent circuit diagram of the motor
First motor
Pr.
82
90
91
92
93
94
859
298
*1
For the FR-A820-03160(55K) or lower, and FR-A840-01800(55K) or lower.
*2
For the FR-A820-03800(75K) or higher, and FR-A840-02160(75K) or higher.
Downloaded from
ManualsNet.com
Motor
SF-JR
SF-JR 4P 1.5 kW or lower
SF-HR
SF-JRCA 4P
SF-HRCA
SF-PR
SF-V5RU (1500 r/min series)
SF-V5RU (other than the 1500 r/min series) 1
L1×L2
I2
R1: Primary resistance
R2: Secondary resistance
I1: Primary leakage inductance
I2: Secondary leakage inductance
R2/S
M: Excitation inductance
S: Slip
L1= I1+ M: Primary inductance
L2= I2+ M: Secondary inductance
Second
Name
motor Pr.
Motor excitation current (no load
455
current)
458
Motor constant (R1)
459
Motor constant (R2)
Motor constant (L1)/d-axis
460
inductance (Ld)
Motor constant (L2)/q-axis
461
inductance (Lq)
462
Motor constant (X)
Torque current/Rated PM motor
860
current
560
Frequency search gain
search engine
2
M
)×100(%)
Setting range
0 to 500 A, 9999
0 to 3600 A, 9999
0 to 50 Ω, 9999
0 to 400 mΩ, 9999
0 to 50 Ω, 9999
0 to 400 mΩ, 9999
0 to 6000 mH, 9999
0 to 400 mH, 9999
0 to 6000 mH, 9999
0 to 400 mH, 9999
0 to 100%, 9999
0 to 500 A, 9999
0 to 3600 A, 9999
0 to 32767, 9999
Pr.71 setting
0 (initial value)
20
40
1
50
70
30
Setting
increments
*1
*1
0.01 A
*2
*2
0.1 A
*1
*1
0.001 Ω
*2
*2
0.01 mΩ
*1
*1
0.001 Ω
*2
*2
0.01 mΩ
*1
*1
0.1 mH
*2
*2
0.01 mH
*1
*1
0.1 mH
*2
*2
0.01 mH
*1
0.1%
*2
0.01%
*1
*1
0.01 A
*2
*2
0.1 A
1
5.13 (C) Motor constant parameters
1
2
3
4
5
6
7
8
9
10
Initial value
9999