• When the load has reversed the rotation opposite to the torque polarity, the setting of Pr.809 Reverse rotation speed
limit/reverse-side speed limit is applied for the speed limit. (The speed limit value and reverse-side speed limit value are
limited at Pr.1 Maximum frequency (maximum 400 Hz under Vector control).)
Rotation speed
Speed limit value
Reverse-side
speed limit value
Start signal
 Speed limit mode 3 (Pr.1113 = "1")
• Select this mode when the torque command is positive. The forward rotation command is for power driving (such as
winding) and the reverse rotation command is for regenerative driving (such as unwinding). (Refer to each following
figures.)
• When Pr.807 Speed limit selection = "0, 2", the setting during speed control is applied for the speed limit. When Pr.807
Speed limit selection = "1", Pr.808 Forward rotation speed limit/speed limit is applied for the speed limit.
Downloaded from
ManualsNet.com
Reverse-side
Torque
speed limit value
command
-Pr.809
value
Speed limit value
-Speed limit value
Reverse-side
speed limit value
Range where torque
control is available
Pr.7
-Pr.809
OFF
ON
When the torque command value is positive
search engine
Range where torque
control is available
Rotation speed
Pr.809
Rotation speed
Pr.8
Reverse-side
speed limit value
Time
Speed limit value
Start signal
When the torque command value is negative
5.4 Torque control under Real sensorless vector control and Vector control
Range where torque
control is available
Pr.809
Pr.7
OFF
ON
1
2
3
4
5
6
7
Time
Pr.8
8
9
10
291