Mitsubishi Electric FR-A800 Series Instruction Manual page 51

Hide thumbs Also See for FR-A800 Series:
Table of Contents

Advertisement

 Type FM (FR-A800-GF)
Sink logic
Main circuit terminal
Control circuit terminal
Three-phase
AC power
supply
Control input signals
(No voltage input allowed) 
Forward rotation start
Reverse rotation start
Start self-holding selection
Multi-speed
Middle speed
selection
Jog operation
Second function selection
Terminal 4 input selection
(Current input selection)
Selection of automatic restart
after instantaneous
Contact input common
(Common for external power supply transistor)
24V external power
Common terminal
Frequency setting signals (Analog)
Frequency setting
potentiometer
1/2W1kΩ 
Auxiliary
input
Terminal 4 input
(Current input)
Safety stop signal
Safety stop input (Channel 1)
Safety stop input (Channel 2)
Safety stop input common
*1
For the FR-A820-03800(75K) or higher, the FR-A840-02160(75K) or higher, or whenever a 75 kW or higher motor is used, always connect a DC
reactor (FR-HEL), which is available as an option. Refer to
When a DC reactor is connected to the FR-A820-03160(55K) or lower or the FR-A840-01800(55K) or lower, if a jumper is installed across
terminals P1 and P/+, remove the jumper before installing the DC reactor. (The jumper is not installed for the FR-A820-03800(75K) or higher and
the FR-A840-02160(75K) or higher.)
50
2. INSTALLATION AND WIRING
2.4 Terminal connection diagrams
Downloaded from
ManualsNet.com
DC reactor
(FR-HEL) 
Jumper
Earth
(Ground)
P1
MC
MCCB
R/L1
S/L2
T/L3
R1/L11
Jumper

S1/L21
Earth
(Ground)
STF
STR
STP(STOP)
RH
High speed
RM
RL
Low speed

JOG
RT
MRS
Output stop
RES
Reset
AU
CS
power failure
SD
PC
24VDC power supply
+24
supply input
SD
10E(+10V)
10(+5V)
3
0 to 5VDC
2
2
0 to 10VDC selectable
0 to 20mADC
5
1
(Analog common)
0 to ±10VDC
(+)
1
0 to ±5VDC selectable
(-)
4 to 20mADC
(+)
4
0 to 5VDC
(-)
0 to 10VDC
PU connector
USB A connector
USB mini B connector
24V
Shorting wire
PC
S1
S2
Output shutoff
circuit
SIC
SD
search engine
Brake resistor
(FR-ABR)  
Brake unit
R
(Option)
Jumper
P/+
PX
PR
N/-
R
U
Inrush current
V
limit circuit
W
ON
EMC filter
ON/OFF
connector
OFF
Main circuit
Control circuit
C1
B1
A1
C2
B2
A2
RUN
SU
IPF
OL
FU
SE
24V
PORT 1
PORT 2
Connector 2
Voltage/current
Connector 3

input switch
ON
F/C
OFF
(FM)
2
4

Initial value
SD

AM
Initial value
5

Initial value
TXD+

selectable
TXD-
RXD+
RXD-
GND
(SG)
Terminating
VCC
resistor
So
(SO)
SOC
page 826
to select the right DC reactor according to the applicable motor capacity.
FR-A820-00770(15K) to 01250(22K),
FR-A840-00470(18.5K) to 01800(55K)
DC reactor
(FR-HEL) 
Jumper
Earth

(Ground)
P1
P/+
P3
Inrush
current
limit circuit
Motor
M
Earth (Ground)
Relay output 
Relay output 1
(Fault output)
Relay output 2
Open collector output 
Running
Up to frequency
Instantaneous
power failure
Overload
Frequency detection
Open collector output common
Sink/source common
CC-Link IE Field Network
communication connector
Connector for plug-in option
connection
+
-
Indicator
(Frequency meter, etc.)
Calibration
Moving-coil type
resistor 
1mA full-scale
(+) Analog signal output
(0 to ±10VDC)
(-)
RS-485 terminals
Data
transmission
Data
reception
GND
5V
(Permissible load current 100mA)
Safety monitor output
Safety monitor output common
Brake resistor 
Brake unit
(Option)
R
PR
N/-