 Setting separately for forward and reverse rotation (Pr.1113 = "9999",
Pr.807 = "1")
• Sets speed limits for forward and reverse directions individually by using Pr.808 Forward rotation speed limit/speed
limit Pr.809 Reverse rotation speed limit/reverse-side speed limit.
• When Pr.809 = "9999" (initial value), speed limit is determined by the setting value of Pr.808 for both forward and reverse
rotations.
Speed limit
150
Output torque
(%)
Speed limit
 Forward/reverse rotation speed limit using analog input (Pr.1113 =
"9999", Pr.807 = "2")
• When performing speed limit by analog inputs to terminal 1, speed limit can be switched between forward and reverse
rotation by its voltage polarity.
• When Pr.868 Terminal 1 function assignment = "5", forward/reverse speed limit is enabled.
• If 0 to 10 V is input, forward rotation speed limit is applied. Reverse rotation speed limit at this time is the value of Pr.1
Maximum frequency.
• If -10 to 0 V is input, reverse rotation speed limit is applied. Forward rotation speed limit at this time is the value of Pr.1
Maximum frequency.
Downloaded from
ManualsNet.com
Speed
Torque controllable range
Forward rotation
Pr.808
150
0
Pr.809
Reverse rotation
search engine
Forward rotation
Pr.7
Speed limit
Speed limit
Reverse rotation
STF(STR)
ON
5.4 Torque control under Real sensorless vector control and Vector control
Pr.8
Pr.808
Time
Time
Time
Pr.809
Pr.809
Pr.809
Torque controllable range
Torque controllable range
Torque controllable range
OFF
5. PARAMETERS
1
2
3
4
5
6
7
8
9
10