M-84
Programming (cont'd)
STEP 8:
AFRS - Assign the number Pattern Code (NPC) and Outgoing route selection pattern (OPR) to the
dummy route.
STEP 9:
AOPR - Assign the route number, including the alternative route to the outgoing route selection
pattern (OPR). Assigns the number of skipped digits and pattern number location (PNL) to each route.
STEP 10: ARSC - Release the dummy route and station connection restriction.
Release the connection restriction on the route of the MF line and station.
FCCS Programming
This data setting describes only the additional or replacement commands used to activate FCCS
services. When used as an FCCS feature, these commands replace the non-network commands (for
example, AAED is replaced by AAEDN). Note that the data setting for FCCS service varies depending
on the node.
STEP 1:
ANPDL - Assign the first digit of the MF line access code.
STEP 2:
ASPAL - Assign the LCR or LCR (S) access code by providing a dummy route.
STEP 3:
ARNPL - Assign the access code to the route number. When multiple access codes are present by
alternative routing, set one of them.
STEP 4:
ARTDN - MF line- Assign the following data, depending on the trunk type, as shown below:
TRUNK
TYPE
OGT
ICT
BWT
Dummy route-Assign 1 at all times for CDN 13:AC. The route data of the dummy route is TCL = 1,
AC = 1 and L/T = 1.
For the others, assign 0 in all cases.
Assign the following route class data to the route of the MF line.
TCMN = 0, TCMC = 0, MFSP: MF Sending Speed.
KPST: Duration of KP sending,
KPPT: Pause after KP sending,
CNI:
CNI Calling Number Identification format (=1)
Assign CDN 22:CNI = 1.
STEP 5:
AFRSL - Assign the number Pattern Code (NPC) and Outgoing route selection pattern (OPR) to the
dummy route.
STEP 6:
AOPRL - Assign the route number, including the alternative route to the outgoing route selection
pattern (OPR). Assigns the number of skipped digits and pattern number location (PNL) to each route.
STEP 7:
ARSCN - Release the dummy route and station connection restriction.
Release the connection restriction on the route of the MF line and station.
Note:
When using ASYDL or ASYDN to program an FCCS feature, the basic programming of ASYD is required
in addition to ASYDL or ASYDN.
Page 534
MF Signaling - DID
Note
OSGS
ONSG
7
4
0
0
7
4
ISGS
INSG
0
0
7
4
7
4
NEAX2400 IPX Feature Programming Manual
LSG
DISPLAY
5
1
5
1
5
1
NDA-24297, Issue 1