S-10
Programming (cont'd)
Provided that "1" is flagging in Bit 0 of Index 576 (System Data 1), let every Local Node recognize its
belonging Center Node for centralized billing-Fusion. Assign data on Center Node FPC at each Local
Node. Given this data, the Local Nodes can acknowledge the SMDR polling only from the Center
Node specified here (the polling from other parties will be ignored).
At the Center Node, assign 00H.
System Data 1, Index 578-581, Bit 0. Assign proper data (0/1) for regulation of output text format
pattern for centralized billing-Fusion. Index 578 corresponds to SMDR A, 579 to SMDR B, 580 to
SMDR C and 581 to SMDR D. The pattern to be adopted will be:
Bit 0 = 0:
Bit 0 = 1:
System Data 1, Index 582, Bit 0-3. Assign the number of nodes to be polled at once.
0000 = 1
0110 = 6
This data is valid when the data is assigned at SYS1, Index 512.
Note 1:
For the numbers more than 8, assign the data value as 8.
Note 2:
System Data 1, Index 583, Bit 0-2. The timing for Fusion billing data transmission from the node that
accommodates the outgoing trunk or the node that accommodates the called station to the node that
accommodates the calling party (Valid when SYS 1, Index 583, b7 = 0 in ASYDN).
Bit
2 1 0
0 0 0 = 8 seconds
0 0 1 = 2 seconds
0 1 0 = 4 seconds
0 1 1 = 6 seconds
System Data 1, Index 608-639.
Fusion Point Code (FPC) of SMDR polling destination.
Page 680
Station Message Detail Recording (SMDR)
ICS text format.
IMX format.
0001 = 1
0010 = 2
0111 = 7
1000 = 8
Bit
2 1 0
1 0 0 = 8 seconds
1 0 1 = 10 seconds
1 1 0 = 12 seconds
1 1 1 = 14 seconds
0011 = 3
0100 = 4
NEAX2400 IPX Feature Programming Manual
0101 = 5
1111 = 8
Note 2
NDA-24297, Issue 1