C-76
Interactions (cont'd)
6.
If OVERFLOW-UCD [O-13] is programmed, overflow to the second group will take place if all stations
in the first group are either busy or in the busy-out state. There will be no CALL WAITING LAMP-UCD
indication to the first group.
7.
If the overflow group is all busy, queuing takes place to the first group and the CALL WAITING LAMP-
UCD will light to indicate a queuing condition at the first group.
8.
When a UCD station is assigned as the destination station of LDN Night Connection, this service cannot
be activated.
9.
For the FCCS network, this feature is available only for UCD stations in the same node as the UCD
controlling station. For more information, see UNIFORM CALL DISTRIBUTION [U-1].
Programming
STEP 1:
ASYD - System Data 1, Index 61, Bit 5. Is UCD Call Waiting Lamp - in service? 0/1: No/Yes.
STEP 2:
ASHU/ASHUL - Assign stations to UCD group.
STEP 3:
AUCD/AUCDL - UCD Call Waiting Lamp threshold value. This command assigns the number of
calls in UCD queue before the UCD Call Waiting Lamp flashes.
TN/UGN:
STN/TELN: Assign station number/Telephone Number in the UCD group. After one station is
QTH ACT:
QTH:
MCI:
CWT:
1-255:
When programming the data, initialize the ELC card which accommodates the UCD group station.
Note:
STEP 4:
AKYD - The Call Waiting Lamp must be assigned to a programmable line/feature key to a D
Assign Type:Function:CALL WAITING LAMP [47].
FCCS Programming
This data setting describes only the additional or replacement commands used to activate FCCS
services. When used as an FCCS feature, these commands replace the non-network commands (for
example, AAED is replaced by AAEDN). Note that the data setting for FCCS service varies depending
on the node.
STEP 1:
ASYDN - This data must be assigned to the NCN.
System Data 1, Index 60, b3: 0/1= UCD Queuing is used/not used.
STEP 2:
AUCDN - These data must be assigned to the NCN.
UCD Call Waiting Lamp threshold value. This command assigns the number of calls in UCD queue
before the UCD Call waiting Lamp flashes.
UGN:
TELN:
QTH ACT:
QTH:
Page 236
Call Waiting Lamp - UCD
Tenant Number/User Group Number (Fixed to "1")
assigned in the group, all stations in the group will automatically have the same
threshold value.
UCD Queueing Peg Count Value Valid/Invalid (1/0)
UCD Queueing Peg Count Value (0-255)
Message Center Interface Data Transfer Valid/Invalid (1/0)
Call Waiting Threshold Value (1-255)
Quantity of calls in UCD queue before the UCD Call Waiting Lamp will begin to flash.
Note 1
User Group Number
UCD Telephone Number
0/1=UCD Queuing Peg Count Value Invalid/Valid
UCD Queuing Peg Count Value (0-255)