NEC NEAX2400 IPX Programming Manual page 720

Feature programming manual
Hide thumbs Also See for NEAX2400 IPX:
Table of Contents

Advertisement

Service Conditions (cont'd)
Example 6
Node A collects the billing information of Node B, Node C and Node D, which are stored in Node B by
polling method.
Node D sends the billing information to Node B.
FCCS - Center Node
IPX
Node A
SMDR
Equipment
SOCKET Interface (LAN Interface) Conditions
1.
SMDR data can be output via LAN cable.
2.
A maximum of four SMDR apparatuses per node are available.
3.
When providing this feature with LAN interface, IMX text format must be designated by the ASYDL
command (SYS 1, Index 578-581, b0).
4.
SMDR apparatus with LAN interface and SMDR apparatus with RS232C interface cannot be connected
to the same node.
NEAX2400 IPX-UMG Conditions
1.
When the system is IPX-UMG, SMDR equipment (PC) is connected via RS232C/LAN to SP.
2.
The maximum of calls available for concurrent storage in the system memory is:
IPX-UMG
Relocation condition for SMDR
When relocating a SMDR equipment to other node, reassign the billing information-related data. The relocation
conditions are shown below.
1.
Make sure there is no billing information in the each node from Center Node before changing the SMDR
location. (Ex. Make sure billing information is output to the SMDR by sending test signal.)
2.
An exact billing information may not be output to SMDR while changing SMDR location.
3.
When removing the SMDR equipment from the Center Node, first of all, delete the billing information-
related data, and also when connecting the SMDR to new-Center Node, the user must, first of all, assign
appropriate billing information-related data.
NEAX2400 IPX Feature Programming Manual
NDA-24297, Issue 1
Station Message Detail Recording (SMDR)
FCCS Network
Billing information of
36546
Node B, D
55213
25454
75213
Polling
ignores
FCCS
IPX
FCCS
Node C
Node C
47,000 times the number of LMGs
CCIS - Center Node
IPX
Billing information of
Node D
Node B
CCIS
SMDR
Equipment
FCCS
: Fusion Call Control Signal (FCCS)
: Common Channel Inter-Office Signaling (CCIS)
DPC:
Destination Point Code
S-10
non IPX
36456
DPC0:
26543
25454
Node B
75213
Node C
Node D
Page 677

Advertisement

Table of Contents
loading