NEC NEAX2400 IPX Programming Manual page 705

Feature programming manual
Hide thumbs Also See for NEAX2400 IPX:
Table of Contents

Advertisement

S-9
Service Conditions (cont'd)
d.) A station can belong to one hunting group only; it cannot belong to another group including that
for STATION HUNTING - CIRCULAR [S-7] or UNIFORM CALL DISTRIBUTION (UCD)
[U-1].
e.) When all stations to be hunted are busy, the incoming call is forwarded finally to the Secretarial
Station. However, when the station is not assigned or is also busy, busy tone is provided to the
caller.
f.) A station, which has already been a member of an existing hunting group by the Physical Station
Number (referred to below as the "feature via DM"), can also be a member of the additional
hunting group by the telephone number (referred to below as the "feature via LDM").
g.) Station Hunt groups via DM and groups via LDM cannot coexist in a system.
h.) The "feature via LDM" cannot be used via FCCS, even though telephone numbers are used.
i.) A Phantom Telephone Number assigned the telephone number for a pilot station, can also be a
pilot number via the APHNL command setting (see Interactions).
12.
An ISDN terminal cannot hunt.
13.
A station within a Circular Hunt Group may deny hunting function for an incoming call originated from
a station (including PS and ATT). Service Condition are as follows:
a.) Incoming trunk call (including C.O./ISDN line) is not available.
b.) When CALL FORWARDING - DON'T ANSWER or CALL FORWARDING - BUSY LINE is
set to a station within Circular Hunt Group, a call to the pilot station is forwarded according to
their service condition.
c.) Assign ASYD System Data 1, Index 439, bit 7=1, and allow SFI 181 of a station which denies
hunting function.
14.
This feature may be activated via FCCS.
15.
The maximum number of Secretarial Stations in the FCCS network is 4,096.
16.
When activating this feature via FCCS, the maximum number of stations per group is 100.
17.
When activating this feature via FCCS, only the telephone number is allowable for the station assignment
of this feature.
18.
When activating this feature via FCCS, the station which has already been assigned as the pilot station of
a Hunt Group-Terminal, the UCD controlling station, or a station of Circular Hunt Group cannot be
assigned to the other Hunt Group-Terminal.
19.
When using the FCH card:
a.) Stations in four different nodes can be assigned to a Hunt Group.
Page 662
Station Hunting - Terminal
NEAX2400 IPX Feature Programming Manual
NDA-24297, Issue 1

Advertisement

Table of Contents
loading

Table of Contents