rpr-ieee atd-timer value
rpr-ieee atd-timer value
Use this command to configure the attribute discovery (ATD) timer, which controls the frequency of
ATD packet transmissions on the IEEE 802.17b based RPR interface.
Syntax Description
Parameter
value
Defaults
Default is 1 second.
Command Modes
IEEE 802.17b based RPR interface configuration
Usage Guidelines
The ATD timer value is very rarely changed. This is usually done only if other equipment uses a different
ATD value or has processor limitations and cannot handle frames at one per second.
Examples
In this example, interface is shortened to int.
router(config)# int rpr-ieee 0
router(config-if)# rpr-ieee atd-timer 1
Related Commands
None
Cisco ONS 15454 and Cisco ONS 15454 SDH Ethernet Card Software Feature and Configuration Guide, R8.0
A-12
Description
Value expressed in seconds. Range is 1 through 10.
Appendix A Command Reference