Cisco ONS 15454 SDH Configuration Manual page 365

Hide thumbs Also See for ONS 15454 SDH:
Table of Contents

Advertisement

Chapter 21 Configuring RMON
Command
Step 3
rmon alarm number ifInErrors.ifIndex-number interval
{absolute | delta} rising-threshold value [event-number]
falling-threshold value [event-number]
[owner string]
Step 4
end
Step 5
show running-config
Step 6
copy running-config startup-config
Below is an example of configuring an SNMP trap for the CRC error threshold.
ML_Series # configure terminal
ML_Series(config)# rmon event 10 log trap slot15 owner config
ML_Series(config)# rmon alarm 9 ifInErrors.983043 300 delta rising-threshold 1000 10
falling-threshold 1000 10 owner config
ML_Series(config)# end
ML_Series # show running-config
ML_Series # copy running-config startup-config
The ifIndex number of an ML-Series card interface in decimal form used for the rmon alarm command
in the example is ifInErrors.983043. This variable is the MIB object to monitor combined with the
ifIndex number of an ML-Series card interface. For information on determining the ifIndex number for
an ML-Series card, see the
page
Below is an example of a rising-threshold trap generated by 1002 ifInErrors crossing a threshold of 1000
in a 5-minute period.
"Determining the ifIndex Number for an ML-Series Card" section on
21-18.
Cisco ONS 15454 and Cisco ONS 15454 SDH Ethernet Card Software Feature and Configuration Guide, R8.0
Configuring an SNMP Trap for the CRC Error Threshold Using Cisco IOS
Purpose
Set an alarm on the MIB object.
For number, specify the alarm number. The
range is 1 to 65535.
The ifIndex-number variable is the ifIndex
number of an ML-Series card interface in
decimal form. (For information about
determining this number, see
ifIndex Number for an ML-Series Card" section
on page
21-18.)
For interval, specify the time in seconds the
alarm monitors the MIB variable. The range is
1 to 4294967295 seconds.
Specify the absolute keyword to test each MIB
variable directly. Specify the delta keyword to
test the change between samples of a MIB
variable.
For value, specify a number at which the alarm
is triggered and a number at which the alarm is
reset. The range for the rising threshold and
falling threshold values is –2147483648 to
2147483647.
(Optional) For event-number, specify the event
number to trigger when the rising or falling
threshold exceeds its limit.
(Optional) For owner string, specify the owner
of the alarm.
Return to privileged EXEC mode.
Verify your entries.
(Optional) Save your entries in the configuration
file.
"Determining the
21-17