2. Monitor Screens

2.17.1 Setting Common Variables

Operation method (Setting "135.000" in variable No. 102)
(1) Press the menu Variabl No .
(2) Designate the variable No.
102 INPUT
The cursor can be moved to 102 using the
↑ , ↓ ,
(3) Input a value.
135 INPUT
The value can also be set by pressing the
menu =INPUT instead of the INPUT
key.
The value can also be input as an
exponential.
(1.35E2 INPUT or 1.35E2
Operation method (Adding "1.234" to variable No. 102)
(1) Select common variable 102 with the
same procedure as steps (1) and (2)
above.
(2) Input a value.
1.234 +INPUT
Operation method (Setting "COUNTER" as the variable name for variable No. 509)
(1) Select common variable 509 with the
same procedure as steps (1) and (2)
above.
(2) Press the
(3) Input the variable name.
COUNTER INPUT
(Note) The variable name can be set only for variable Nos. 500 to 519.
and
keys.
=INPUT .)
key.
The menu is highlighted.
The common variable for the set No. appears at the head.
The set value appears.
The value obtained by adding the input value to the original
value appears.
(Example) If the original value is 135.000, 136.234
appears. (135.000 + 1.234 = 136.234)
The cursor appears at the cursor 509 variable position.
The cursor moves to the 509 variable name.
"COUNTER" appears.