Mitsubishi Electric 700 Series Training Manual page 143

Hide thumbs Also See for 700 Series:
Table of Contents

Advertisement

3. Setup Screen
<Without the touch sensor (simple measurement)>
(5) Move the tool in the X-direction to the
arbitrary position and press the menu
SkipPos take in
(6) Select the workpiece coordinate system
offset in which the measurement data will
be set.
(Example) Press the menus
Coord G54-G59
G55.
(7) Press the
Coord write
(8) Carry out the operations in steps (4) to (7)
in the same way for the Y and Z axes.
(9) Return the tool to the reference position,
and turn the measurement switch OFF.
.
G55
to select
menu.
3.7 Workpiece Measurement
The skip position is calculated and the result displays in the
measurement counter X axis section.
The value achieved by adding or subtracting the external
workpiece offset to or from the X axis measurement position
based on the "#1237 set09 BITO" value (external workpiece
offset symbol conversion) is set in workpiece coordinate
system selected at (6).
The measurement counter displays blank.
The message "On meas" disappears.