Mitsubishi Electric 700 Series Training Manual page 64

Hide thumbs Also See for 700 Series:
Table of Contents

Advertisement

2. Monitor Screens
Operation method (Canceling the manual numerical value command)
The manual numerical value command mode is canceled by carrying out one of the following operations
before pressing the INPUT key.
Press the menu Close
Press the
Change the screen
Setting/output range of manual numerical value command
The manual numerical value command setting range is shown below.
S
M
T
B
Add a "-" sign before the value to set a negative value. The display will be a positive value.
A value larger than "#3001 slimt1" to "#3004 slimt4" or "#3005 smax1" to "#3008 smax4"cannot be
output for S.
key
BCD
-
0 to 99999999
0 to 99999999
0 to 99999999
2.13 Manual Numerical Value Command
Signed binary
-99999999 to 99999999
-
-
-
56