6. Maintenance Screens
"8205 OT+" Setting X1 axis to "100.0" and Z1 axis to "200.0"
(1) Press the menu Axis param .
(2) Use the
and
cursor to the position to be set.
(The row does not need to be designated
with the
and
(3) Input the value.
(Format: 1st row/2nd row/3rd row/4th row)
100//200 INPUT
(Note 1) If PR appears at the lower right of the screen when the parameter value is changed, the
parameter value will be validated when the power is turned ON again.
(Note 2) If the INPUT key is pressed without inputting a value, the cursor will move without changing
the parameter setting value.
(Note 3) If a character string, such as an axis name or input/output device name, is set in the parameter,
the setting will be cleared when 0 is input and the INPUT key is pressed.
(Note 4) Parameters for up to four rows, which are as currently displayed, can be set at once.
(Note 5) If the parameter value for several rows is input simultaneously, the values will be set from the
currently displayed left end no matter which row the cursor is currently at.
keys to move the
keys.)
236
The cursor moves to the position of the setting target data.
The current setting value is displayed in the input area.
The setting value appears, and the cursor moves.
6.1 Parameter Screens