Origin Set, Origin Cancel - Mitsubishi Electric 700 Series Training Manual

Hide thumbs Also See for 700 Series:
Table of Contents

Advertisement

2. Monitor Screens

2.12 Origin Set, Origin Cancel

Origin set and origin cancel can be executed.
Menus
Menu
The origin is set.
Origin
When main menu G92 set
set
highlighted and the origin set mode is activated.
The origin is canceled.
Origin
cancel
The origin cancel mode is activated when this menu is pressed.
This closes the pop-up window and quits this function.
Close
Differences between origin set and origin cancel
Function
Changes in the
counter value
Offset
Details
is pressed, the menu Origin set
Origin set
The coordinate system is shifted so the current
position becomes the designated position of the
workpiece coordinate system.
This is equivalent to "G92 X0". (When X is the
target axis.)
The relative position counter and workpiece
coordinate counters become "0".
The G92 shift amount is updated.
2.12 Origin Set, Origin Cancel
is
The coordinate system is shifted so the zero
point of the workpiece coordinate system
matches the zero point of the basic machine
coordinate system.
This is equivalent to "G92 G53 X0". (When X is
the target axis.)
The relative position counter matches the
machine coordinate counter.
The G92 shift amount and the G52 shift amount
for the G54 to G59 coordinate system becomes
"0".
53
Type
Reference
A
A
C
Origin cancel

Advertisement

Table of Contents
loading

This manual is also suitable for:

70 series

Table of Contents