2. Monitor Screens
Menus
Menu
This starts the restart search based on the designated device,
Search
directory, program number (O), sequence number (N), block number
exec
(B) and number of block execution times (P).
This changes to the pop-up window for executing top search, and
enables top search.
Top
search
When the type 1 is selected or the parameter "#8914 Auto Top search"
is set, this menu cannot be selected.
This selects the restart search type. Restart search is executed with
Type1
the highlighted restart type.
The type 1 or type 2 menu is always highlighted.
When restart search is executed, the selected restart type is displayed
Type2
at the display item "(3) Restart type".
This changes to the pop-up window for setting the file, and enables
File set
the file to be selected.
This opens the MSTB history screen as a pop-up window.
The M, S, T and B command used in the machining program are listed
MSTB
on the MSTB history screen. If the cursor is moved to the listed M, S,
history
T or B command and the INPUT key is pressed, that command will
be executed.
This closes the pop-up window and quits this function.
Close
Details
30
2.3 Restart Search
Type
Reference
C
B
2.3.2 Top Search Screen
B
B
2.3.3 File Setting Screen
B
2.3.4 MSTB History
Screen